01Power & Distribution Cables
Low-voltage mains, medium-voltage feeders, screened single-core cables and armoured distribution constructions.
Explore RangeCable Products
Find armoured power cables, screened instrumentation pairs, control and equipment cable, marine and mining constructions, overhead conductors and solar PV cable. Search a model or standard, filter the required layers, or compare two products.
Cable Products
Start with the circuit duty, then open the range to compare cable types and specifications.
01Low-voltage mains, medium-voltage feeders, screened single-core cables and armoured distribution constructions.
Explore Range
02LSZH fixed wiring, alarm circuits, fire-resistant mains and mineral-insulated cable constructions.
Explore Range
03Control conductors, screened instrument pairs, telecommunications and industrial communication cable groups.
Explore Range
04Fixed building wiring, panel and equipment connections, flexible control, rubber and silicone constructions.
Explore Range
05BS 6708 mining cables, IEC shipboard wiring, marine power and instrumentation, and NEK 606 constructions.
Explore Range
06Bare conductors, overhead insulated cables, PV energy cable and screened renewable-network connections.
Explore RangeCable Construction
Already know the required layers? Filter by conductor, insulation, screen, armour and outer sheath.

1.5–16 mm² · PVC (Polyvinyl Chloride)
Armoured cable for fixed power and auxiliary control wiring in factories, plant rooms and other industrial installations. This 1.5–16 mm² BS 5467 range combines copper conductors, XLPE insulation…

1kV · Polyvinyl Chloride PVC
BS5467 armoured copper mains cable for fixed power distribution, in the 25–400 mm² range. XLPE insulation, steel-wire armour and a PVC sheath make up this 1 kV mains…

600/1000 Volts · PVC
Utility control cable for fixed connections between electrical equipment and its operating controls. The 600/1000 V construction combines stranded copper, PVC insulation and sheath, and galvanised steel-wire armour.

1kV · Medium Density Polyethylene (MDPE)
BS 5467 armoured cable for fixed wiring and smaller mains circuits, in the 4–16 mm² range. Copper conductors and XLPE insulation sit inside steel-wire armour and an MDPE…

1kV · Polyvinyl Chloride (PVC)
Solid-aluminium BS 5467 cable for fixed 1 kV mains and distribution circuits. The 25–300 mm² range has XLPE insulation, PVC bedding and sheath, and galvanised steel-wire armour.

1kV · Medium Density Polyethylene (MDPE)
Copper BS 5467 mains cable with an MDPE outer sheath, for fixed 1 kV distribution circuits in the 25–400 mm² range. XLPE insulation and steel-wire armour provide the…

1900/3300 Volts · PVC
6941AX armoured mains cable with copper conductors, XLPE insulation and a PVC sheath. This 50–1000 mm² range is rated 1900/3300 V and uses aluminium-wire armour.

1900/3300 Volts · Polyvinyl Chloride PVC
Three-core BS 5467 cable for fixed 3.3 kV power feeders. It combines Class 2 copper conductors and XLPE insulation in one steel-wire-armoured, PVC-sheathed cable, with a 1900/3300 V…

1900/3300 Volts · PVC
Copper 6941AX mains cable for 3.3 kV power connections, in the 120–630 mm² range. XLPE insulation, aluminium-wire armour and a PVC sheath form the 1900/3300 V construction.

6350/11000 volts · PVC outer sheath
Three-core aluminium cable for 6.35/11 kV distribution feeders. Each XLPE-insulated core has a copper-tape screen, with galvanised steel-wire armour and a PVC outer sheath around the assembly.

6350/11000 Volts - Tested to Voltage and Duration of BS 6622 · PVC outer sheath
Three-core 6.35/11 kV cable for fixed distribution connections between switchgear, transformers and other power equipment. Compacted copper conductors, XLPE insulation and copper-tape screening are enclosed by steel-wire armour…

6350/11000 Volts - Tested to Voltage and Duration of BS 6622 · PVC outer sheath
Single-core 6.35/11 kV cable for fixed links between switchgear, transformers and other distribution equipment. It combines compacted copper conductors, XLPE insulation, copper-tape screening and aluminium-wire armour, with PVC…

Uo/U 19kV/33kV · Medium Density Polyethylene (MDPE)
Single-core aluminium cable for the 19/33 kV distribution network of a renewable-energy installation. XLPE insulation, a copper-wire screen and an MDPE sheath form the BS 7870 construction.

Uo/U 19kV / 33kV · Medium Density Polyethylene (MDPE)
Single-core copper service cable for 19/33 kV network connections. The BS 7870 construction has XLPE insulation, a copper-wire screen and an MDPE outer sheath.

600/1000 Volts · Polyvinyl Chloride (PVC)
Single-core armoured cable for cathodic-protection system wiring. The 600/1000 V construction has stranded copper, XLPE insulation, steel-wire armour and a PVC sheath, in the 6–185 mm² range.

600/1000 Volts · Polyethylene (PE)
Armoured feeder cable connecting a traffic-detection loop to its detector equipment. Solid copper, PE insulation and bedding, steel-wire armour and a PE sheath form the 1.5–2.5 mm² range.

600/1000V · Polyvinyl Chloride (PVC)
Armoured cable for fixed traffic-signal wiring between controller equipment and the signal installation. The 600/1000 V cable uses solid copper conductors, PVC insulation and sheath, and steel-wire armour.

300/500 Volts · PVC to IEC 60332-1-2
NYMJ cable for fixed domestic and industrial wiring, with PVC insulation and a PVC sheath. The range covers 1.5–16 mm² at 300/500 V.

300/500 Volts · PVC
PVC twin-and-earth cable for fixed building lighting and power wiring. The 300/500 V range combines the circuit conductors and earth connection in one cable, in sizes from 1…

450/750 volts
6491X/H07V-R stranded copper wiring cable for individual circuit conductors in conduit, trunking and equipment enclosures. It has PVC insulation and a 450/750 V rating.

300/500 volts, 120mm2 rated at 600/1000 volts · 1.5–120 mm² · PVC
PVC-insulated and PVC-sheathed cable for surface wiring, covering 1.5–120 mm². Sizes below 120 mm² are rated 300/500 V; the 120 mm² version is rated 600/1000 V.

300/500Volts · Halogen free thermoplastic polymer compound
NHXMH-J cable for fixed domestic and industrial wiring. Copper conductors have XLPE insulation and a halogen-free thermoplastic sheath, with a 300/500 V rating in the 1.5–10 mm² product…

450/750 Volts · Low Smoke and Zero Halogen (LSZH)
6491B/H07Z-R wiring cable for individual conductors in protected building and equipment wiring. It combines compacted stranded copper with LSZH material at 450/750 V.

300/500 Volts · Low Smoke Zero Halogen (LSZH)
LSZH twin-and-earth cable for fixed building circuits. This 300/500 V BS 7211 range uses XLPE insulation and an LSZH sheath, in sizes from 1 to 16 mm².

450/750 Volts · 1.5–35 mm² · Low Smoke and Zero Halogen (LSZH)
6181B surface-wiring cable with XLPE insulation and an LSZH sheath, rated 450/750 V. The 1.5–35 mm² range uses solid conductors through 2.5 mm² and stranded copper above 2.5…

300/500V · Low Smoke Zero Halogen (LSZH)
Enhanced fire-alarm and security cable for 300/500 V system wiring. The construction uses mica-tape or silicone-rubber fire-resistant insulation, an aluminium/polyester screen and an LSZH sheath.

300/500V · Low Smoke Zero Halogen (LSZH)
Standard fire-alarm and security cable for 300/500 V circuits. Mica-tape or silicone-rubber fire-resistant insulation is combined with an aluminium/polyester screen, a circuit protective conductor and an LSZH sheath.

300/500 volts · Low Smoke Zero Halogen (LSZH)
Flexible cord for equipment connections requiring LSZH insulation and sheath. The 318*B/H05ZIZI-F range uses flexible stranded copper and is rated 300/500 V, with a -15°C to +70°C temperature…

300/500 Volts · LSZH
YY cable for flexible equipment-control wiring with LSZH insulation and sheath. Stranded copper conductors form the 300/500 V connection, in sizes from 0.75 to 25 mm².

300/500 Volts · Low Smoke Zero Halogen (LSZH)
CY flexible control cable with copper conductors, LSZH insulation and an LSZH sheath. The 300/500 V range covers 0.75–2.5 mm² equipment-control connections.

300/500 volts · LSZH
SY control cable for equipment wiring requiring steel-wire armour and LSZH materials. It combines stranded copper, LSZH insulation and sheath, and a 300/500 V rating in the 1.5–6…

Flexible single-core copper cable for individual equipment-wiring connections. The 2491B/6701B range has LSZH covering, covers 0.75–240 mm², and has a -15°C to +90°C temperature range.

6350/11000 Volts Volts - Tested to Voltage and Duration of BS7835 · Low Smoke Zero Halogen (LSZH)
Three-core 6.35/11 kV cable for distribution feeders requiring LSZH bedding and sheath. Compacted copper conductors and XLPE insulation are enclosed by copper-tape screening and steel-wire armour.

6350/11000 Volts - Tested to Voltage and Duration of BS 7835 · LSZH
Single-core 6.35/11 kV cable with LSZH bedding and sheath for medium-voltage power connections. Compacted copper, XLPE insulation, copper-tape screening and aluminium-wire armour form the BS 7835 construction.

11000V · Medium Density Polyethylene (MDPE)
Triplex aluminium power cable for 11 kV network distribution. XLPE-insulated cores have copper-wire and copper-tape screening and an MDPE sheath. The triplex arrangement groups the power cables together…

22000 Volts · Low Smoke Zero Halogen (LSZH)
Three-core 22 kV power cable for feeders requiring an armoured LSZH construction. Compacted copper conductors, XLPE insulation, semiconductive screens and copper-tape screening sit inside steel-wire armour and LSZH…

600V-1000V AC, 1800V DC · Cross-linked halogen-free compound
Solar PV cable for the DC wiring between panels and array equipment. The flexible Class 5 tinned-copper conductor helps route connections at the modules, with cross-linked halogen-free insulation…

230-415V · PCP (Polychloroprene) to BS EN 50363
Flexible H07RN-F cable for temporary equipment-power leads. Class 5 copper conductors, EPR insulation and a PCP sheath provide a rubber-cable construction for the stated 230–415 V lead range.

230-415V · Transparent PVC
SY temporary-power cable with stranded copper, PVC insulation and a galvanised steel-wire braid under a transparent PVC sheath. The 2.5–4 mm² lead range is rated 230–415 V.

640V to 1100V · Heavy duty chloroprene outer sheath
BS 6708 Type 20 cable for mining and quarry power connections. Flexible Class 5 tinned copper, EPR insulation and a heavy-duty chloroprene sheath are combined with galvanised pliable…

640V to 1100V · Heavy duty chloroprene outer sheath
BS 6708 Type 21 mining cable with flexible tinned-copper conductors, EPR insulation, pliable steel armour and a heavy-duty chloroprene sheath.

640V to 1100V · Heavy duty chloroprene outer sheath
Type 7 mining power cable with screened phase cores, an unscreened pilot and an uninsulated ground core. Flexible tinned copper, EPR insulation and a heavy-duty chloroprene sheath form…

640V to 1100V · Heavy duty chloroprene outer sheath
Type 7M mining cable for power connections requiring screens over both phase and pilot cores. It uses flexible tinned copper, EPR insulation and a heavy-duty chloroprene sheath, with…

1900V to 3300V · Heavy duty chloroprene outer sheath
BS 6708 Type 307 cable for mining-machine power connections. Screened phase cores, an unscreened pilot and an uninsulated ground core are combined with flexible tinned copper, EPR insulation…

1900V to 3300V · Heavy duty chloroprene outer sheath
Type 321 mining and quarry power cable with flexible tinned-copper conductors, EPR insulation and galvanised pliable armour. The heavy-duty chloroprene sheath forms the outer covering of the 35–120…

1900V to 3300V · Heavy duty chloroprene outer sheath
Type 331 mining power cable combining screened phase cores with galvanised pliable armour. Flexible tinned copper, EPR insulation and a chloroprene sheath form the 25–120 mm² range.

Low Smoke Zero Halogen (LSZH)
BS 8436 cable for protected fixed wiring, using stranded copper, XLPE insulation and a bonded aluminium tube beneath an LSZH sheath. The minimum installation temperature is 0°C.

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Armoured copper mains cable for fixed 600/1000 V distribution circuits requiring LSZH bedding and sheath. The BS 6724 range combines XLPE insulation and steel-wire armour in sizes from…

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
BS 6724 cable for fixed branch-power and auxiliary-control circuits requiring LSZH materials. Copper conductors, XLPE insulation and steel-wire armour are combined with LSZH bedding and sheath at 600/1000…

600/1000 Volts · Polyvinyl Chloride (PVC)
NYCY power cable for fixed 600/1000 V connections, with solid copper conductors, PVC insulation and a PVC sheath. The 1.5–16 mm² range has a fixed-service temperature range of…

600/1000 Volts · LSZH (Low Smoke Zero Halogen) Type HM4
Non-armoured N2XH cable for fixed 600/1000 V power distribution. Copper conductors have XLPE insulation and an LSZH sheath, in the 1.5–400 mm² range.

600/1000 Volts · 1.5–16 mm² · PVC (Poly Vinyl Chloride)
Non-armoured NYYJ cable for fixed mains and control wiring. The 600/1000 V range uses PVC insulation and sheath and covers 1.5–16 mm² circuits.

600/1000 Volts · Low Smoke and Zero Halogen (LSZH)
Single-core copper mains cable for 600/1000 V connections with separate power conductors. The BS 8573 6181B range uses XLPE insulation and an LSZH sheath, in sizes from 50…

1kV · Polyvinyl Chloride PVC
Copper BS 5467 mains cable for fixed 1 kV power distribution. XLPE insulation, PVC bedding, steel-wire armour and a PVC sheath form the 25–400 mm² range.

600/1000 Volts · LSZH
6941AB power cable for 600/1000 V connections requiring LSZH bedding and sheath. Compacted copper conductors, XLPE insulation and aluminium-wire armour form the 50–1000 mm² range.

50–1000 mm² · PVC
6181X single-core mains cable for individual large-section power connections. The 50–1000 mm² range uses copper conductors with XLPE insulation and a PVC sheath.

600/1000 · PVC
Non-armoured 6181X cable for cathodic-protection wiring. A single stranded copper conductor has XLPE insulation and a PVC sheath, with a 600/1000 V rating in the 6–185 mm² range.

600/1000 volts · 6–95 mm² · High-Molecular Weight Polyethylene (HMWPE)
Single-core cathodic-protection cable with PVDF insulation and an HMWPE sheath. The non-armoured copper range covers 6–95 mm² at 600/1000 V, with a -55°C to +105°C temperature range.

1900/3300 · Low Smoke Zero Halogen (Low Smoke Zero Halogen)
Three-core 3.3 kV mains cable with XLPE-insulated copper conductors, steel-wire armour and LSZH bedding and sheath. The BS 6724 range covers 16–300 mm² at 1900/3300 V.

1900 to 3300 Volts · Low smoke Zero Halogen (LSZH)
6941AB mains cable in the 3.3 kV range, with stranded copper conductors, XLPE insulation and aluminium-wire armour. LSZH bedding and sheath surround the 120–630 mm² construction.

600/1000 volts · Low Smoke and Zero Halogen (LSZH)
Fire-resistant single-core cable for individual conductors in an emergency-circuit wiring system. The 6491F range combines stranded copper and LSZH covering at 600/1000 V, in sizes from 1.5 to…

600/1000 volts · LSZH
F2 fire-resistant mains cable for 600/1000 V power circuits, in sizes from 1.5 to 16 mm². Copper conductors and XLPE insulation are combined with steel-wire armour, LSZH bedding…

600/1000 volts · LSZH
Armoured F2 fire-resistant cable for larger 600/1000 V power feeders. The 25–400 mm² range uses copper conductors, XLPE insulation and LSZH bedding and sheath.

600/1000 volts · Low Smoke Zero Halogen (LSZH)
F120 enhanced fire-resistant mains cable for 600/1000 V circuits, with BS 7846 and BS 8491 references. The 4–16 mm² construction combines copper, XLPE insulation, steel-wire armour and LSZH…

600/1000 volts · Low Smoke Zero Halogen (LSZH)
F120 enhanced fire-resistant cable for larger 600/1000 V mains feeders, in sizes from 25 to 400 mm². Copper conductors, XLPE insulation, steel-wire armour and LSZH outer materials form…

600/1000 volts · Poly Vinyl Chloride (PVC)
Split-concentric cable for 600/1000 V utility supply and service connections. The 4–35 mm² range uses stranded copper, XLPE insulation and a PVC sheath.

600/1000 volts · Poly Vinyl Chloride (PVC)
Straight-concentric cable for 600/1000 V supply connections under the BS 7870 and ESI 09-7 product references. Stranded copper conductors have PVC insulation and a PVC sheath, in sizes…

300/500 Volts · PVC
Flexible YY control cable for machine and equipment wiring. Stranded copper conductors have PVC insulation and a PVC sheath, with a 300/500 V rating in the 0.75–50 mm²…

300/500 Volts · Transparent PVC
SY flexible control cable with galvanised steel-wire braid beneath a transparent PVC sheath. Stranded copper conductors and PVC insulation form the 300/500 V equipment-control connection.

300/500 Volts · Polyvinyl Chloride (PVC)
Screened CY cable for flexible machine-control connections. A tinned-copper braid surrounds the PVC-insulated copper conductors beneath a PVC sheath, with a 300/500 V rating.

Solid Copper Sheath
Mineral-insulated cable for circuits requiring a solid copper sheath around copper conductors and magnesium-oxide insulation. The BS 6207 MICC range offers a metal-sheathed alternative to polymer-insulated wiring.

300/500 volts · Polyvinyl Chloride (PVC)
Individually screened PAS 5308 Part 1 Type 1 cable for instrumentation and process-control signals. Copper conductors, PE insulation and a PVC sheath form the 300/500 V range.

300/500 Volts · LSZH
LSZH-sheathed instrumentation cable with a separate screen around each PE-insulated copper pair. Each pair has a 0.5 mm² drain wire, providing individual screen connections for the 300/500 V…

300/500 volts · Polyvinyl Chloride (PVC)
Overall-screened PAS 5308 Part 1 Type 1 cable for measurement and control signals. PE-insulated copper conductors share an aluminium/Mylar tape screen with a 0.5 mm² drain wire beneath…

300/500 Volts · LSZH
Overall-screened instrumentation cable with copper conductors, PE insulation and an LSZH sheath. The PAS 5308 Part 1 Type 1 range is rated 300/500 V for measurement and control…

300/500 volts · Polyvinyl Chloride (PVC)
PAS 5308 Part 2 Type 1 cable for overall-screened instrumentation connections. Copper conductors have PVC insulation, bedding and sheath, with an aluminium/Mylar tape screen and a 0.5 mm²…

300/500 volts · Polyvinyl Chloride (PVC)
Individually screened instrumentation cable for measurement and control circuits. The PAS 5308 Part 2 Type 1 range uses copper conductors with PVC insulation and sheath at 300/500 V.

300/500 Volts · Polyvinyl Chloride (PVC)
Armoured instrumentation cable with individually and collectively foil-screened copper pairs. PE insulation, steel-wire armour and a PVC outer sheath form the 300/500 V Part 1 Type 2 construction.

300/500 Volts · Low Smoke Zero Halogen (LSZH)
Armoured instrumentation cable for measurement and control signals between field instruments, junction boxes and control panels. Each PE-insulated pair has a foil screen, and a collective screen surrounds…

300/500 volts · Polyvinyl Chloride (PVC)
Armoured PAS 5308 Part 1 Type 2 cable for instrument circuits requiring an overall screen. PE-insulated copper pairs share an aluminium/Mylar tape screen and a 0.5 mm² drain…

300/500 Volts · Low Smoke Zero Halogen (LSZH)
Armoured instrumentation cable with an overall foil screen and LSZH bedding and sheath. PE-insulated copper pairs share a 0.5 mm² drain wire in the 300/500 V Part 1…

300/500 Volts · Polyvinyl Chloride (PVC)
Individually screened, armoured instrumentation cable under PAS 5308 Part 2 Type 2. Copper pairs have PVC insulation, bedding and sheath, with steel-wire armour and a 300/500 V rating.

300/500 volts · Polyvinyl Chloride (PVC)
Overall-screened, armoured cable for instrumentation and control signals. The 300/500 V PAS 5308 Part 2 Type 2 construction uses copper pairs with PVC insulation, PVC bedding, steel-wire armour…

Polyvinyl Chloride (PVC)
Non-armoured BS 4937 range for thermocouple-extension and compensating-cable enquiries. PVC insulation and sheath are combined with an overall foil screen.

600/1000 Volts · Halogen free extruded SHF1 compound
Shipboard power cable with tinned copper conductors, XLPE insulation and an SHF1 halogen-free sheath. The IEC 60092-353 range is rated 600/1000 V and covers 1.5–25 mm² circuits.

150/250 volts · Low Smoke Zero Halogen (LSZH) SW4
Individually screened marine instrumentation cable for fixed measurement and control connections. Tinned-copper pairs, triples or quads have EPR GP4 insulation, with steel-wire braid and an LSZH SW4 sheath…

150/250 volts · Low Smoke Zero Halogen (LSZH) SW4
Overall-screened cable for fixed marine instrument connections. EPR GP4-insulated tinned-copper pairs, triples or quads share a foil screen, with steel-wire braid and an LSZH SW4 sheath at 150/250…

150/250 Volts · Low Smoke Zero Halogen (LSZH) SW4
Fire-resistant marine instrumentation cable with individually screened circuit groups. Tinned-copper pairs, triples or quads use mica-glass tape and EPR GP4 insulation beneath steel-wire braid and an LSZH SW4…

150/250 volts · Low Smoke Zero Halogen (LSZH) SW4
Overall-screened fire-resistant cable for marine instrumentation. Mica-glass tape and EPR GP4 insulate the tinned-copper groups, with steel-wire braid and an LSZH SW4 sheath at 150/250 V.

600/1000 Volts · Low smoke zero halogen (LSZH) SW4
Marine power cable for smaller fixed circuits in the 1.5–6 mm² range. The 657*TQ construction uses tinned copper, EPR insulation and an LSZH SW4 sheath at 600/1000 V.

600/1000 Volts · Low smoke zero halogen (LSZH) SW4
657*TQ marine power cable for feeders and equipment supplies in the 10–630 mm² range. Tinned-copper conductors have EPR insulation and an LSZH SW4 sheath, with a 600/1000 V…

600/1000 Volts · Low smoke zero halogen (LSZH) SW4
Marine power cable with steel-wire braid for smaller 600/1000 V circuits. The 1.5–4 mm² 658*TQ range combines tinned copper, EPR insulation and LSZH bedding and sheath.

600/1000 Volts · Low smoke zero halogen (LSZH) SW4
Braided marine power cable for larger 600/1000 V circuits, in sizes from 6 to 300 mm². The 658*TQ construction has tinned copper conductors, EPR insulation, steel-wire braid and…

600/1000 volts; instrumentation circuits: 150-250 Volts · Mud resistant sheath
BFOU cable range for offshore power and instrumentation connections. Copper conductors and EPR insulation are enclosed by tinned-copper wire braid, halogen-free mud-resistant bedding and a mud-resistant sheath.

Power Cable 600/1000 Volts; instrumentation circuits: 150-250 Volts · Mud resistant sheath
RFOU power and instrumentation cable for offshore routes specifying mud-resistant bedding and sheath. The NEK 606 construction combines copper conductors, EPR insulation and tinned-copper wire braid.

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Flexible Class 5 copper power cable for equipment connections, with XLPE insulation and an LSZH sheath. This 600/1000 V range has a +90°C temperature rating and a minimum…

1800/3000V · Polychloroprene (PCP)
Flexible NSGAFÖU cable for equipment-power connections, with tinned copper conductors, EPR insulation and a PCP sheath. The range is rated 1800/3000 V.

450/750 Volts · Thermoplastic Rubber (TPR)
Flat flexible cable for equipment-power and control connections using a flat cable route. Copper conductors have TPR insulation and sheath at 450/750 V, with a -35°C to +65°C…

300/500 volts · Silicone
Silicone-insulated flexible cable for equipment wiring in high-temperature areas. Tinned-copper conductors have silicone insulation and sheath, with a 300/500 V rating and a -60°C to +180°C temperature range.

PVC
Flexible PVC cord for appliance and equipment connections, in the 0.5–2.5 mm² H05V2V2-F range.

440 Volt · Low Smoke Zero Halogen (LSZH)
Screened cable for equipment-control and signal wiring under the DEF 61-12 reference. Flexible tinned-copper conductors have LSZH insulation and sheath and a tinned-copper braid screen, rated 440 V.

440 volts · Polyvinyl Chloride (PVC)
Small-conductor cable for equipment-control and signal connections. The DEF 61-12 PVC range combines flexible tinned copper and a tinned-copper braid screen at 440 V, in sizes from 0.22…

33000 Volts · Low Smoke Zero Halogen (LSZH)
Three-core 33 kV power cable for feeders requiring steel-wire armour and LSZH outer materials. Compacted copper conductors, XLPE insulation, semiconductive screens and copper-tape screening form the BS 7835…

600/1000 Volts · Polychloroprene (PCP)
Flexible loop-detector cable for traffic-detection wiring, in sizes from 1.5 to 2.5 mm². Tinned copper has EPR insulation and a PCP sheath, with a 600/1000 V rating.

110kV
XLPE-insulated power cable for 110 kV network connections.

220kV
XLPE-insulated power cable for 220 kV transmission connections.

500kV
XLPE-insulated power cable for 500 kV transmission connections.

Steel-cored aluminium stranded conductor for overhead transmission and distribution lines. The steel core provides reinforcement within the conductor.

Aluminium stranded conductor for overhead power-line connections.



0.63 mm · PVC
Screened, armoured cable for fixed telecommunications and signalling connections. Solid 0.63 mm copper conductors have cellular PE insulation, with an aluminium/Mylar screen, steel-wire armour and a PVC sheath.

Polyethylene
Jelly-filled telecommunications cable with solid copper conductors, cellular PE insulation and a PE sheath. Steel-wire armour surrounds the petroleum-jelly-filled PE bedding for the fixed cable route.

0.64 mm · PVC sheath
Screened ENATS 09-6 cable for utility telecommunications. Tinned-copper pairs of 0.64 mm conductor diameter share a foil screen and a 0.5 mm² drain wire, with steel-wire armour and…

0.50 mm · PVC sheath
ENATS 09-6 telecommunications cable with 0.50 mm solid-copper conductors and PE insulation and bedding. Steel-wire armour and a PVC sheath form the outer construction.

0.50 mm · Polyvinyl Chloride (PVC)
Screened utility telecommunications cable with 0.50 mm copper conductors, PVC insulation and a collective aluminium/Mylar foil screen. A 0.5 mm² drain wire, steel-wire armour and PVC sheath complete…

0.28 mm · PVC sheath
Armoured telecommunications cable for utility circuits using 0.28 mm tinned-copper pairs. PVC insulation and bedding are enclosed by steel-wire armour and a PVC sheath.

0.50 mm · Polyvinyl Chloride (PVC)
ENATS 09-6 cable for fixed utility telecommunications, using 0.50 mm solid-copper conductors. PVC insulation and bedding sit inside steel-wire armour and a PVC outer sheath.

0.64 mm · PVC sheath
Armoured utility telecommunications cable with 0.64 mm tinned-copper pairs. The ENATS 09-6 construction uses PVC insulation and bedding, galvanised steel-wire armour and a PVC sheath.

6/10 (12)kV · Polyethylene (PE)
Copper medium-voltage power cable rated 6/10 (12) kV, with XLPE insulation and a PE sheath. The N2XS(F)2Y construction includes a copper-wire screen and counter-helix copper tape.

6/10 (12)kV · Polyethylene (PE)
N2XS2Y copper power cable rated 6/10 (12) kV, with XLPE insulation, a semiconductive compound layer and a PE sheath. Use the full voltage designation when matching this range…

22kV · PE
N2XS(F)2Y 22 kV power cable with XLPE insulation and a PE sheath, in the 35–630 mm² range.

22kV · PE
N2XS2Y cable for 22 kV power connections, with XLPE insulation and a PE outer sheath. The product range covers 35–500 mm².

12/20kV · PE
NA2XS2Y medium-voltage power cable with XLPE insulation and a PE sheath, in the 12/20 kV, 50–240 mm² range.

33kV · PE
N2XS2Y power cable in the 33 kV range, with XLPE insulation and a PE sheath. The product group covers 50–500 mm².

LSZH
LSZH-sheathed CAT cable range for communication, control and measurement connections under BS EN 50288-7.

LSZH
ICAT communication and control cable range under BS EN 50288-7, with an LSZH outer sheath.

PVC
PVC-sheathed CAT cable range for communication and control connections under BS EN 50288-7.

PVC
PVC-sheathed ICAT cable range for communication and control connections.

CSP
Flexible 318*TQ cable for equipment mains and control connections, with EPR insulation and a CSP sheath. The range covers 0.75–2.5 mm².

Tough-rubber flexible cord for equipment connections in the 0.75–2.5 mm² range, with EPR insulation.

CSP
Flexible 638*TQ mains cable for larger equipment-power connections. The 25–630 mm² range uses EPR insulation and a CSP sheath.

CSP
638*TQ flexible mains cable for equipment connections in the 4–16 mm² range. EPR insulation and a CSP sheath form the specified material construction.

Bare hard-drawn copper conductor in the 50–70 mm² range, under BS 7884.

Bare soft-drawn copper for earthing, bonding and other non-insulated electrical connections. The BS 6360/81 range covers 6–400 mm².

Flexible single-core 6381Y cable for individual equipment and installation connections. The PVC-insulated BS 6004 range covers 6–400 mm².

CSP
Coil-end lead cable connecting winding ends to equipment terminals. The BS 6195/69 Type 4 range uses EPR insulation and a CSP sheath.

PVC-insulated panel and equipment wire in the Tri-Rated cable range, covering 0.5–400 mm² under the BS 6231 reference.

CSP
0361TQ welding cable for the welding-machine output and return connections. EPR insulation and a CSP sheath form the 16–185 mm² lead range.

PCP
Braided tough-rubber flexible cord with a PCP outer sheath, for equipment connections in the 1–16 mm² range.

LSZH
6591TQ marine cable for service and equipment connections, with EPR insulation and an LSZH sheath. The BS 6883 range covers 6–630 mm².

LSZH
Fire-resistant marine cable under the BS 7917/6883 reference, with mica-glass tape, steel-wire braid and an LSZH sheath. The range covers 1.5–16 mm².

LSZH
Flexible single-core 6381B cable for individual power and equipment connections. XLPE insulation and an LSZH sheath form the 16–300 mm² range.

11kV · MDPE
Power cable for 11 kV distribution connections, with XLPE insulation and an MDPE outer sheath, in sizes from 95 to 300 mm².

PCP
H07RN-F flexible mains and control cable with EPR insulation and a PCP sheath, covering 1–630 mm² equipment connections.

1–16 mm² · LSZH
H07ZZ-F/318*ZH flexible mains and control cable with an LSZH sheath, in the 1–16 mm² range.

LSZH
Flexible H07ZZ-F cable for larger mains and control connections, with an LSZH outer sheath in the 25–630 mm² range.

PVC
H07VVH6-F flat cable for equipment power and control connections. PVC insulation and a PVC sheath form the 1.5–95 mm² range.

LSZH
PROFIBUS cable range for industrial communication links, with an LSZH outer sheath and a BS EN/IEC 61158 reference.

NEK 606 RFOU cable range for offshore power and instrumentation enquiries, in the 1.5–35 mm² group.

Non-armoured loop feeder for the connection between a traffic-detection loop and its detector equipment. The BS 6346/87 range covers 1.5–2.5 mm².
No products match the current filters.
Product Comparison
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS5467 Mains Cable - SWA, PVC, 1kV | BS5467 Solid Aluminium Core Mains Cable - SWA, PVC, 1kV |
|---|---|---|
| Conductor | Class 2 stranded copper conductor acc BS EN 60228 (previously BS 6360) | Solid Aluminium |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Bedding / Inner Sheath | Polyvinyl Chloride (PVC) | Polyvinyl Chloride (PVC) |
| Armour | Steel Wire Armour (SWA) | Galvanised Steel Wire Armour (SWA) |
| Outer Sheath | Polyvinyl Chloride PVC | Polyvinyl Chloride (PVC) |
| Temperature Range | Fixed -20°C to +90°C | Fixed -20°C to +90°C |
| Voltage Designation | 1kV | 1kV |
| Standard Reference | BS5467 · BS EN 60332-1 | BS5467 · BS EN 60332 |
Standards and Testing
Find products under the standard in your specification, then read the linked guide to understand its scope.
BS5467
Cable Construction
Cable Construction →BS6622
Voltage Designations
Voltage Designations →BS6724
Insulation and Outer Materials
Insulation and Outer Materials →BS6708
Conductor and Protective Layers
Conductor and Protective Layers →PAS5308 / BS5308
Screen Positions
Screen Positions →IEC60332 / BSENIEC60332
Flame Propagation
Flame Propagation →IEC61034 / BSEN50268
Smoke Characteristics
Smoke Characteristics →IEC60754 / BSEN50267 / BSENIEC60754
Gas Characteristics
Gas Characteristics →Cable Products
Start with your industry to see relevant cable ranges and the features that matter at the connection.

Prysm Cable supplies screened 11 kV and 33 kV feeders, low-voltage armoured mains and utility control cable for fixed connections around substations…
Application Details ↗
Armoured mains for distribution, LSZH wires for fixed building wiring, and separate fire-alarm and fire-resistant mains ranges for essential circuits. Prysm Cable…
Application Details ↗
Control wiring, instrument loops, fieldbus links and equipment power make different demands on an automation cable. Our range includes YY, SY and…
Application Details ↗
Prysm Cable’s BS6708 range covers Type 20 armoured equipment cable, Type 7 and 7M screened constructions, and Type 307 cable. Separate armoured…
Application Details ↗
Prysm Cable supplies shipboard power and instrument cables, including screened marine pairs and a BFOU mud-resistant range. The cable choice follows the…
Application Details ↗
From solar array wiring to plant-network feeders, auxiliary power and monitoring, Prysm Cable offers separate cable ranges for each connection. The PV…
Application Details ↗
Armoured telecom pairs, screened instrumentation and PROFIBUS cables serve different signal systems. Prysm Cable’s range separates those connection types so the cable…
Application Details ↗
Prysm Cable supplies PAS5308 instrument pairs for field measurements, armoured LSZH instrumentation for protected plant routes, and separate auxiliary mains and temperature-instrument…
Application Details ↗Cable Products
Compare the conductor material together with the selected size, finished dimensions and connections.
For an XLPE-insulated cable, choose the bedding and sheath separately: our BS 5467 option uses PVC coverings and BS 6724 uses LSZH.
Our single-core 11 kV feeder uses AWA; the three-core feeder uses SWA. Match the armour to the core arrangement and AC circuit design.
Select an overall screen around the assembly, individual pair screens, or both according to the instrument schedule.
Cable Products
Explore power, control and instrumentation selections for bridge services, a wind-farm substation and an automated storage cell.

The bridge lighting upgrade shares a service route with maintenance power and essential electrical circuits. The cable package separates ordinary fixed feeders, LSZH-specified enclosed routes and fire-resistant mains, using BS5467, BS6724 and F2 cable for those different duties.
Engineering Story ↗
The onshore substation connects the wind development’s medium-voltage network with local auxiliary supplies and monitoring. Prysm Cable’s package brings together 19/33 kV service cable, armoured LSZH mains and individually screened instrument pairs, with the electrical and signal duties kept distinct.
Engineering Story ↗
The storage cell adds fixed power, control and PROFIBUS interfaces to an existing production area. The cable choices address two practical constraints: space at the cabinet entries and electrical screening around the drives. N2XH power cable, CY control cable and a dedicated bus cable serve those separate interfaces.
Engineering Story ↗Product Data
Print a product summary or download its listed construction and technical data as CSV.