Power Networks & Distribution
Power networks combine low-voltage distribution, medium-voltage feeders and overhead conductors. Conductor, insulation, screen and armour vary across underground, substation and overhead routes.

Cable Application
Prysm Cable supplies screened 11 kV and 33 kV feeders, low-voltage armoured mains and utility control cable for fixed connections around substations and distribution equipment.
Application Detail
Power networks combine low-voltage distribution, medium-voltage feeders and overhead conductors. Conductor, insulation, screen and armour vary across underground, substation and overhead routes.
Operator networks use split or straight concentric service cables alongside medium-voltage feeder and triplex constructions. Each operator specifies its own acceptance criteria for the product and connection.
BS6622 3 Core Aluminium Mains Cable 11kV - XLPE, SWA, PVC
BS6622 3 Core Mains Cable 11kV - XLPE, SWA, PVCThree-core BS6622 feeders for 11 kV distribution, with copper or aluminium conductors. Both use XLPE insulation, a copper-tape screen, SWA and PVC coverings.
Single-core BS7870 copper service cable for a 19/33 kV connection, with a copper-wire screen and an MDPE sheath.
Copper BS5467 mains for the fixed low-voltage supplies serving equipment and site services, with XLPE insulation, SWA and PVC coverings.
BS7870-8 armoured control cable for auxiliary circuits around utility equipment, rated 600/1000 V.
Application Detail
A three-core feeder groups the phases inside one steel-wire armour. A single-core AC feeder uses non-magnetic aluminium-wire armour; its cable formation and screen/armour bonding form part of the installation design. The choice affects the route, handling and terminations as well as the cable order.
Aluminium can reduce conductor cost and weight, but the proposed size, finished diameter and compatible connections can change. Compare the designed feeder sizes and their accessories, particularly when an alternative must fit existing switchgear.
Application Detail
View specifications or add cables to your enquiry.

6350/11000 volts · PVC outer sheath
Three-core aluminium cable for 6.35/11 kV distribution feeders. Each XLPE-insulated core has a copper-tape screen, with galvanised steel-wire armour and a PVC outer sheath around the assembly.

6350/11000 Volts - Tested to Voltage and Duration of BS 6622 · PVC outer sheath
Three-core 6.35/11 kV cable for fixed distribution connections between switchgear, transformers and other power equipment. Compacted copper conductors, XLPE insulation and copper-tape screening are enclosed by steel-wire armour…

6350/11000 Volts - Tested to Voltage and Duration of BS 6622 · PVC outer sheath
Single-core 6.35/11 kV cable for fixed links between switchgear, transformers and other distribution equipment. It combines compacted copper conductors, XLPE insulation, copper-tape screening and aluminium-wire armour, with PVC…

Uo/U 19kV / 33kV · Medium Density Polyethylene (MDPE)
Single-core copper service cable for 19/33 kV network connections. The BS 7870 construction has XLPE insulation, a copper-wire screen and an MDPE outer sheath.

1kV · Polyvinyl Chloride PVC
BS5467 armoured copper mains cable for fixed power distribution, in the 25–400 mm² range. XLPE insulation, steel-wire armour and a PVC sheath make up this 1 kV mains…

600/1000 Volts · PVC
Utility control cable for fixed connections between electrical equipment and its operating controls. The 600/1000 V construction combines stranded copper, PVC insulation and sheath, and galvanised steel-wire armour.
Product Data
Print a product summary or download its listed construction and technical data as CSV.
Application Detail
The two figures describe different electrical stresses: 6.35 kV from conductor to earth and 11 kV between phases. They are the U₀/U rating. A higher voltage used during a cable test is a separate test condition, not permission to operate that cable continuously on a higher-voltage network.
Read MoreFor an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read More