Low-Voltage Distribution
Copper armoured mains for fixed feeders between distribution equipment and plant, with PVC bedding and sheath.
Cable Range
Armoured LV mains, screened 11 kV and 33 kV feeders, and concentric service cables for fixed power distribution. Choose copper or aluminium conductors, single-core AWA or multicore SWA, and PVC, MDPE or LSZH coverings to match the circuit schedule.

Cable Range
Start with the feeder voltage and core arrangement, then select the specified conductor metal, armour and outer covering.
Copper armoured mains for fixed feeders between distribution equipment and plant, with PVC bedding and sheath.
An armoured feeder with LSZH bedding and sheath for routes carrying a low-smoke, zero-halogen materials requirement.
Three phases in one steel-wire-armoured cable for the specified 11 kV feeder arrangement.
Separate single-core AC runs using non-magnetic AWA; cable formation and bonding are part of the installation design.
A copper 19/33 kV single-core service cable with copper-wire screening and an MDPE sheath.
Split-concentric service cable with XLPE insulation and a PVC sheath, rated 600/1000 V.

1.5–16 mm² · PVC (Polyvinyl Chloride)
Armoured cable for fixed power and auxiliary control wiring in factories, plant rooms and other industrial installations. This 1.5–16 mm² BS 5467 range combines copper conductors, XLPE insulation…

1kV · Polyvinyl Chloride PVC
BS5467 armoured copper mains cable for fixed power distribution, in the 25–400 mm² range. XLPE insulation, steel-wire armour and a PVC sheath make up this 1 kV mains…

1kV · Medium Density Polyethylene (MDPE)
BS 5467 armoured cable for fixed wiring and smaller mains circuits, in the 4–16 mm² range. Copper conductors and XLPE insulation sit inside steel-wire armour and an MDPE…

1kV · Polyvinyl Chloride (PVC)
Solid-aluminium BS 5467 cable for fixed 1 kV mains and distribution circuits. The 25–300 mm² range has XLPE insulation, PVC bedding and sheath, and galvanised steel-wire armour.

1kV · Medium Density Polyethylene (MDPE)
Copper BS 5467 mains cable with an MDPE outer sheath, for fixed 1 kV distribution circuits in the 25–400 mm² range. XLPE insulation and steel-wire armour provide the…

1900/3300 Volts · PVC
6941AX armoured mains cable with copper conductors, XLPE insulation and a PVC sheath. This 50–1000 mm² range is rated 1900/3300 V and uses aluminium-wire armour.

1900/3300 Volts · Polyvinyl Chloride PVC
Three-core BS 5467 cable for fixed 3.3 kV power feeders. It combines Class 2 copper conductors and XLPE insulation in one steel-wire-armoured, PVC-sheathed cable, with a 1900/3300 V…

1900/3300 Volts · PVC
Copper 6941AX mains cable for 3.3 kV power connections, in the 120–630 mm² range. XLPE insulation, aluminium-wire armour and a PVC sheath form the 1900/3300 V construction.

6350/11000 volts · PVC outer sheath
Three-core aluminium cable for 6.35/11 kV distribution feeders. Each XLPE-insulated core has a copper-tape screen, with galvanised steel-wire armour and a PVC outer sheath around the assembly.

6350/11000 Volts - Tested to Voltage and Duration of BS 6622 · PVC outer sheath
Three-core 6.35/11 kV cable for fixed distribution connections between switchgear, transformers and other power equipment. Compacted copper conductors, XLPE insulation and copper-tape screening are enclosed by steel-wire armour…

6350/11000 Volts - Tested to Voltage and Duration of BS 6622 · PVC outer sheath
Single-core 6.35/11 kV cable for fixed links between switchgear, transformers and other distribution equipment. It combines compacted copper conductors, XLPE insulation, copper-tape screening and aluminium-wire armour, with PVC…

Uo/U 19kV / 33kV · Medium Density Polyethylene (MDPE)
Single-core copper service cable for 19/33 kV network connections. The BS 7870 construction has XLPE insulation, a copper-wire screen and an MDPE outer sheath.

6350/11000 Volts Volts - Tested to Voltage and Duration of BS7835 · Low Smoke Zero Halogen (LSZH)
Three-core 6.35/11 kV cable for distribution feeders requiring LSZH bedding and sheath. Compacted copper conductors and XLPE insulation are enclosed by copper-tape screening and steel-wire armour.

6350/11000 Volts - Tested to Voltage and Duration of BS 7835 · LSZH
Single-core 6.35/11 kV cable with LSZH bedding and sheath for medium-voltage power connections. Compacted copper, XLPE insulation, copper-tape screening and aluminium-wire armour form the BS 7835 construction.

11000V · Medium Density Polyethylene (MDPE)
Triplex aluminium power cable for 11 kV network distribution. XLPE-insulated cores have copper-wire and copper-tape screening and an MDPE sheath. The triplex arrangement groups the power cables together…

22000 Volts · Low Smoke Zero Halogen (LSZH)
Three-core 22 kV power cable for feeders requiring an armoured LSZH construction. Compacted copper conductors, XLPE insulation, semiconductive screens and copper-tape screening sit inside steel-wire armour and LSZH…

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Armoured copper mains cable for fixed 600/1000 V distribution circuits requiring LSZH bedding and sheath. The BS 6724 range combines XLPE insulation and steel-wire armour in sizes from…

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
BS 6724 cable for fixed branch-power and auxiliary-control circuits requiring LSZH materials. Copper conductors, XLPE insulation and steel-wire armour are combined with LSZH bedding and sheath at 600/1000…

600/1000 Volts · Polyvinyl Chloride (PVC)
NYCY power cable for fixed 600/1000 V connections, with solid copper conductors, PVC insulation and a PVC sheath. The 1.5–16 mm² range has a fixed-service temperature range of…

600/1000 Volts · LSZH (Low Smoke Zero Halogen) Type HM4
Non-armoured N2XH cable for fixed 600/1000 V power distribution. Copper conductors have XLPE insulation and an LSZH sheath, in the 1.5–400 mm² range.

600/1000 Volts · 1.5–16 mm² · PVC (Poly Vinyl Chloride)
Non-armoured NYYJ cable for fixed mains and control wiring. The 600/1000 V range uses PVC insulation and sheath and covers 1.5–16 mm² circuits.

600/1000 Volts · Low Smoke and Zero Halogen (LSZH)
Single-core copper mains cable for 600/1000 V connections with separate power conductors. The BS 8573 6181B range uses XLPE insulation and an LSZH sheath, in sizes from 50…

1kV · Polyvinyl Chloride PVC
Copper BS 5467 mains cable for fixed 1 kV power distribution. XLPE insulation, PVC bedding, steel-wire armour and a PVC sheath form the 25–400 mm² range.

600/1000 Volts · LSZH
6941AB power cable for 600/1000 V connections requiring LSZH bedding and sheath. Compacted copper conductors, XLPE insulation and aluminium-wire armour form the 50–1000 mm² range.

50–1000 mm² · PVC
6181X single-core mains cable for individual large-section power connections. The 50–1000 mm² range uses copper conductors with XLPE insulation and a PVC sheath.

1900/3300 · Low Smoke Zero Halogen (Low Smoke Zero Halogen)
Three-core 3.3 kV mains cable with XLPE-insulated copper conductors, steel-wire armour and LSZH bedding and sheath. The BS 6724 range covers 16–300 mm² at 1900/3300 V.

1900 to 3300 Volts · Low smoke Zero Halogen (LSZH)
6941AB mains cable in the 3.3 kV range, with stranded copper conductors, XLPE insulation and aluminium-wire armour. LSZH bedding and sheath surround the 120–630 mm² construction.

600/1000 volts · Poly Vinyl Chloride (PVC)
Split-concentric cable for 600/1000 V utility supply and service connections. The 4–35 mm² range uses stranded copper, XLPE insulation and a PVC sheath.

600/1000 volts · Poly Vinyl Chloride (PVC)
Straight-concentric cable for 600/1000 V supply connections under the BS 7870 and ESI 09-7 product references. Stranded copper conductors have PVC insulation and a PVC sheath, in sizes…

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Flexible Class 5 copper power cable for equipment connections, with XLPE insulation and an LSZH sheath. This 600/1000 V range has a +90°C temperature rating and a minimum…

33000 Volts · Low Smoke Zero Halogen (LSZH)
Three-core 33 kV power cable for feeders requiring steel-wire armour and LSZH outer materials. Compacted copper conductors, XLPE insulation, semiconductive screens and copper-tape screening form the BS 7835…

110kV
XLPE-insulated power cable for 110 kV network connections.

220kV
XLPE-insulated power cable for 220 kV transmission connections.

500kV
XLPE-insulated power cable for 500 kV transmission connections.

6/10 (12)kV · Polyethylene (PE)
Copper medium-voltage power cable rated 6/10 (12) kV, with XLPE insulation and a PE sheath. The N2XS(F)2Y construction includes a copper-wire screen and counter-helix copper tape.

6/10 (12)kV · Polyethylene (PE)
N2XS2Y copper power cable rated 6/10 (12) kV, with XLPE insulation, a semiconductive compound layer and a PE sheath. Use the full voltage designation when matching this range…

22kV · PE
N2XS(F)2Y 22 kV power cable with XLPE insulation and a PE sheath, in the 35–630 mm² range.

22kV · PE
N2XS2Y cable for 22 kV power connections, with XLPE insulation and a PE outer sheath. The product range covers 35–500 mm².

12/20kV · PE
NA2XS2Y medium-voltage power cable with XLPE insulation and a PE sheath, in the 12/20 kV, 50–240 mm² range.

33kV · PE
N2XS2Y power cable in the 33 kV range, with XLPE insulation and a PE sheath. The product group covers 50–500 mm².

11kV · MDPE
Power cable for 11 kV distribution connections, with XLPE insulation and an MDPE outer sheath, in sizes from 95 to 300 mm².
No products match the current filters.
Cable Range

Prysm Cable supplies screened 11 kV and 33 kV feeders, low-voltage armoured mains and utility control cable for fixed connections around substations…
Application Details ↗
Armoured mains for distribution, LSZH wires for fixed building wiring, and separate fire-alarm and fire-resistant mains ranges for essential circuits. Prysm Cable…
Application Details ↗
Prysm Cable’s BS6708 range covers Type 20 armoured equipment cable, Type 7 and 7M screened constructions, and Type 307 cable. Separate armoured…
Application Details ↗
From solar array wiring to plant-network feeders, auxiliary power and monitoring, Prysm Cable offers separate cable ranges for each connection. The PV…
Application Details ↗Product Data
Print a product summary or download its listed construction and technical data as CSV.
Cable Range
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreThe two figures describe different electrical stresses: 6.35 kV from conductor to earth and 11 kV between phases. They are the U₀/U rating. A higher voltage used during a cable test is a separate test condition, not permission to operate that cable continuously on a higher-voltage network.
Read More