SPWC-CABLE-084
BS4937 Compensating & Thermocouple Cable - Non-Armoured
Non-armoured BS 4937 range for thermocouple-extension and compensating-cable enquiries. PVC insulation and sheath are combined with an overall foil screen.
| Temperature Range | -30°C to +105°C |
|---|
Product Details
Match the Thermocouple Type
Extension and compensating conductors must match the thermocouple type and polarity of the measurement circuit. State that type in the cable enquiry so the conductor-alloy combination can be confirmed. The cable’s -30°C to +105°C temperature range is separate from the sensor’s measurement range.
Product Details
Cable Construction
01Conductor
Plain Annealed Copper Conductors
02Insulation
Polyvinyl Chloride (PVC)
03Screen
Collective aluminium / Mylar foil tape screen and a 0.5mm2 drain wire
04Outer Sheath
Polyvinyl Chloride (PVC)
05Armour
Non-armoured
Product Details
Electrical and Physical Specifications
- Temperature Range
- -30°C to +105°C
Product Details
Standards and Technical Topics
Individual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreCable Size: Cores, Pairs, mm² and Outside Diameter
“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreProduct Details
Product Technical Data
BS4937 Compensating & Thermocouple Cable - Non-Armoured
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS4937 Compensating & Thermocouple Cable - Non-Armoured | BS6346/87 Armoured Loop Feeder Cable |
|---|---|---|
| Conductor | Plain Annealed Copper Conductors | Plain Annealed Solid Copper |
| Insulation | Polyvinyl Chloride (PVC) | Polyethylene (PE) |
| Screen | Collective aluminium / Mylar foil tape screen and a 0.5mm2 drain wire | Not Listed |
| Outer Sheath | Polyvinyl Chloride (PVC) | Polyethylene (PE) |
| Armour | Non-armoured | Galvanised Steel Wire Armour |
| Bedding / Inner Sheath | Not Listed | Polyethylene (PE) |
| Temperature Range | -30°C to +105°C | -15°C to +70°C |
| Rated Voltage | Not Listed | 600/1000 Volts |
| Standard Reference | BS4937 · ANSI 96.1 · IEC 584 · BS4066 · IEC 332 | BS6346/87 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing