SPWC-CABLE-104
LOOP DETECTOR CABLE - BS6500, BS6195, EPR, PCP
LOOP DETECTOR CABLE - BS6500, BS6195, EPR, PCP - 1.5MM TO 2.5MM
Flexible loop-detector cable for traffic-detection wiring, in sizes from 1.5 to 2.5 mm². Tinned copper has EPR insulation and a PCP sheath, with a 600/1000 V rating.
| Rated Voltage | 600/1000 Volts |
|---|---|
| Temperature Range | -30°C to +85°C |
Product Details
Loop Wire and the Feeder Connection
The detection loop and its feeder are separate parts of the circuit. This is the flexible loop-cable range; our BS 6346/87 armoured loop feeder connects the loop back to its detector equipment. Select each cable for its position in the detector layout.
Product Details
Cable Construction
01Conductor
Tinned Annealed Flexible Copper
02Insulation
Ethylene Propylene Rubber (EPR)
03Outer Sheath
Polychloroprene (PCP)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 600/1000 Volts
- Temperature Range
- -30°C to +85°C
Product Details
Standards and Technical Topics
Individual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreCable Size: Cores, Pairs, mm² and Outside Diameter
“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreProduct Details
Product Technical Data
LOOP DETECTOR CABLE - BS6500, BS6195, EPR, PCP
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | LOOP DETECTOR CABLE - BS6500, BS6195, EPR, PCP | BS6346/87 Armoured Loop Feeder Cable |
|---|---|---|
| Conductor | Tinned Annealed Flexible Copper | Plain Annealed Solid Copper |
| Insulation | Ethylene Propylene Rubber (EPR) | Polyethylene (PE) |
| Outer Sheath | Polychloroprene (PCP) | Polyethylene (PE) |
| Bedding / Inner Sheath | Not Listed | Polyethylene (PE) |
| Armour | Not Listed | Galvanised Steel Wire Armour |
| Rated Voltage | 600/1000 Volts | 600/1000 Volts |
| Temperature Range | -30°C to +85°C | -15°C to +70°C |
| Standard Reference | BS6500 · BS6195 | BS6346/87 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints