N2XH Class 5 Equipment Power
Class 5 copper gives the installer a flexible conductor for the fixed supply entry. The cable bend and gland still need adequate space.
- Rated Voltage
- 600/1000 Volts
- Minimum Bending Radius
- 5 x overall diameter
Industrial Automation
The storage cell adds fixed power, control and PROFIBUS interfaces to an existing production area. The cable choices address two practical constraints: space at the cabinet entries and electrical screening around the drives. N2XH power cable, CY control cable and a dedicated bus cable serve those separate interfaces.

Engineering Detail
The package covers the fixed connections between the plant, local control cabinet and storage-cell equipment. Moving shuttle and cable-chain wiring need their own movement-rated construction; they are outside this fixed-connection package.
Engineering Detail
N2XH Class 5 helps route the fixed power connection into the cabinet, while its stated 5D bending radius still determines the bend space from the finished cable diameter. For the control connection, CY provides a tinned-copper braid screen. SY’s steel braid is a mechanical layer, so it cannot be substituted merely because both cables have a braid. The relevant choice follows the electrical screening requirement.
Engineering Detail

Class 5 copper gives the installer a flexible conductor for the fixed supply entry. The cable bend and gland still need adequate space.

The CY tinned-copper braid provides the specified screen around the control cores, with termination coordinated to the equipment’s grounding arrangement.

A dedicated PROFIBUS cable keeps the communication connection separate from the multicore control wiring; the bus-cable variant must match the equipment.
Engineering Detail
The 5D figure is a bending constraint, not a cycle-life rating. Repeated travel in a cable chain adds bending frequency, speed, stroke and possibly torsion.
Engineering Detail

A cable that can be bent into position is not automatically suitable for repeated machine movement. For a tight route, the useful numbers are the finished cable diameter, the minimum bending radius for that use, and the handling-temperature limit. Conductor class alone cannot answer all three questions.
Read MoreAn overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreTalk to Prysm Cable about the cable types, specifications and installation duties in your project.