LSZH Single-Core Fixed Wiring
Single-core LSZH wire for fixed building wiring. The low-smoke material choice does not by itself establish circuit survival in fire.
Cable Range
LSZH building wiring, fire-alarm cable and fire-resistant mains for distinct circuit duties. Start with fixed wiring, alarm signalling or essential power, then match the voltage, construction and required fire-test classification.

Cable Range
Choose the cable for the circuit duty. LSZH wiring, alarm cable and fire-resistant mains have different construction and evidence requirements.
Single-core LSZH wire for fixed building wiring. The low-smoke material choice does not by itself establish circuit survival in fire.
Twin-and-earth LSZH wiring where the circuit and installation specification calls for that core arrangement.
A 300/500 V enhanced fire-alarm range for the alarm-circuit specification and its required fire test.
A separate standard fire-alarm range. The required test classification determines whether standard or enhanced performance is appropriate.
Armoured 600/1000 V mains for a circuit requiring a fire-resistant power-cable construction.
The enhanced fire-resistant mains range for its specified fire-performance duty; select by the applicable test evidence, not an assumed duration from the product name.

450/750 Volts · Low Smoke and Zero Halogen (LSZH)
6491B/H07Z-R wiring cable for individual conductors in protected building and equipment wiring. It combines compacted stranded copper with LSZH material at 450/750 V.

300/500 Volts · Low Smoke Zero Halogen (LSZH)
LSZH twin-and-earth cable for fixed building circuits. This 300/500 V BS 7211 range uses XLPE insulation and an LSZH sheath, in sizes from 1 to 16 mm².

450/750 Volts · 1.5–35 mm² · Low Smoke and Zero Halogen (LSZH)
6181B surface-wiring cable with XLPE insulation and an LSZH sheath, rated 450/750 V. The 1.5–35 mm² range uses solid conductors through 2.5 mm² and stranded copper above 2.5…

300/500V · Low Smoke Zero Halogen (LSZH)
Enhanced fire-alarm and security cable for 300/500 V system wiring. The construction uses mica-tape or silicone-rubber fire-resistant insulation, an aluminium/polyester screen and an LSZH sheath.

300/500V · Low Smoke Zero Halogen (LSZH)
Standard fire-alarm and security cable for 300/500 V circuits. Mica-tape or silicone-rubber fire-resistant insulation is combined with an aluminium/polyester screen, a circuit protective conductor and an LSZH sheath.

Low Smoke Zero Halogen (LSZH)
BS 8436 cable for protected fixed wiring, using stranded copper, XLPE insulation and a bonded aluminium tube beneath an LSZH sheath. The minimum installation temperature is 0°C.

600/1000 volts · Low Smoke and Zero Halogen (LSZH)
Fire-resistant single-core cable for individual conductors in an emergency-circuit wiring system. The 6491F range combines stranded copper and LSZH covering at 600/1000 V, in sizes from 1.5 to…

600/1000 volts · LSZH
F2 fire-resistant mains cable for 600/1000 V power circuits, in sizes from 1.5 to 16 mm². Copper conductors and XLPE insulation are combined with steel-wire armour, LSZH bedding…

600/1000 volts · LSZH
Armoured F2 fire-resistant cable for larger 600/1000 V power feeders. The 25–400 mm² range uses copper conductors, XLPE insulation and LSZH bedding and sheath.

600/1000 volts · Low Smoke Zero Halogen (LSZH)
F120 enhanced fire-resistant mains cable for 600/1000 V circuits, with BS 7846 and BS 8491 references. The 4–16 mm² construction combines copper, XLPE insulation, steel-wire armour and LSZH…

600/1000 volts · Low Smoke Zero Halogen (LSZH)
F120 enhanced fire-resistant cable for larger 600/1000 V mains feeders, in sizes from 25 to 400 mm². Copper conductors, XLPE insulation, steel-wire armour and LSZH outer materials form…

Solid Copper Sheath
Mineral-insulated cable for circuits requiring a solid copper sheath around copper conductors and magnesium-oxide insulation. The BS 6207 MICC range offers a metal-sheathed alternative to polymer-insulated wiring.

LSZH
Flexible single-core 6381B cable for individual power and equipment connections. XLPE insulation and an LSZH sheath form the 16–300 mm² range.
No products match the current filters.
Product Data
Print a product summary or download its listed construction and technical data as CSV.
Cable Range
An emergency circuit may need to keep working during a fire. An LSZH cable addresses smoke and halogen-related characteristics; a flame-retardant cable addresses flame spread. Neither label alone establishes circuit survival. Choosing the cable starts with the required function of the circuit during the fire.
Read MoreA building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read More