Utility Auxiliary Control
Armoured utility control cable for auxiliary connections around distribution equipment.
Cable Range
Armoured utility control, screened instrument pairs, telecom cable and PROFIBUS options for control and communication systems. Choose the cable for the signal or protocol first, then match the screening, armour and sheath.

Cable Range
Match power-system controls, measurement pairs and protocol-specific communication to their named cable ranges.
Armoured utility control cable for auxiliary connections around distribution equipment.
Traffic-signal cable for the fixed roadside signal connection.
Individually screened pairs for instrument loops where coupling between neighbouring circuits matters.
Armoured screened instrumentation where the route also requires mechanical protection.
A dedicated PROFIBUS communication range; the electrical variant must match the connected fieldbus equipment.

600/1000 Volts · PVC
Utility control cable for fixed connections between electrical equipment and its operating controls. The 600/1000 V construction combines stranded copper, PVC insulation and sheath, and galvanised steel-wire armour.

600/1000 Volts · Polyethylene (PE)
Armoured feeder cable connecting a traffic-detection loop to its detector equipment. Solid copper, PE insulation and bedding, steel-wire armour and a PE sheath form the 1.5–2.5 mm² range.

600/1000V · Polyvinyl Chloride (PVC)
Armoured cable for fixed traffic-signal wiring between controller equipment and the signal installation. The 600/1000 V cable uses solid copper conductors, PVC insulation and sheath, and steel-wire armour.

300/500 volts · Polyvinyl Chloride (PVC)
Individually screened PAS 5308 Part 1 Type 1 cable for instrumentation and process-control signals. Copper conductors, PE insulation and a PVC sheath form the 300/500 V range.

300/500 Volts · LSZH
LSZH-sheathed instrumentation cable with a separate screen around each PE-insulated copper pair. Each pair has a 0.5 mm² drain wire, providing individual screen connections for the 300/500 V…

300/500 volts · Polyvinyl Chloride (PVC)
Overall-screened PAS 5308 Part 1 Type 1 cable for measurement and control signals. PE-insulated copper conductors share an aluminium/Mylar tape screen with a 0.5 mm² drain wire beneath…

300/500 Volts · LSZH
Overall-screened instrumentation cable with copper conductors, PE insulation and an LSZH sheath. The PAS 5308 Part 1 Type 1 range is rated 300/500 V for measurement and control…

300/500 volts · Polyvinyl Chloride (PVC)
PAS 5308 Part 2 Type 1 cable for overall-screened instrumentation connections. Copper conductors have PVC insulation, bedding and sheath, with an aluminium/Mylar tape screen and a 0.5 mm²…

300/500 volts · Polyvinyl Chloride (PVC)
Individually screened instrumentation cable for measurement and control circuits. The PAS 5308 Part 2 Type 1 range uses copper conductors with PVC insulation and sheath at 300/500 V.

300/500 Volts · Polyvinyl Chloride (PVC)
Armoured instrumentation cable with individually and collectively foil-screened copper pairs. PE insulation, steel-wire armour and a PVC outer sheath form the 300/500 V Part 1 Type 2 construction.

300/500 Volts · Low Smoke Zero Halogen (LSZH)
Armoured instrumentation cable for measurement and control signals between field instruments, junction boxes and control panels. Each PE-insulated pair has a foil screen, and a collective screen surrounds…

300/500 volts · Polyvinyl Chloride (PVC)
Armoured PAS 5308 Part 1 Type 2 cable for instrument circuits requiring an overall screen. PE-insulated copper pairs share an aluminium/Mylar tape screen and a 0.5 mm² drain…

300/500 Volts · Low Smoke Zero Halogen (LSZH)
Armoured instrumentation cable with an overall foil screen and LSZH bedding and sheath. PE-insulated copper pairs share a 0.5 mm² drain wire in the 300/500 V Part 1…

300/500 Volts · Polyvinyl Chloride (PVC)
Individually screened, armoured instrumentation cable under PAS 5308 Part 2 Type 2. Copper pairs have PVC insulation, bedding and sheath, with steel-wire armour and a 300/500 V rating.

300/500 volts · Polyvinyl Chloride (PVC)
Overall-screened, armoured cable for instrumentation and control signals. The 300/500 V PAS 5308 Part 2 Type 2 construction uses copper pairs with PVC insulation, PVC bedding, steel-wire armour…

Polyvinyl Chloride (PVC)
Non-armoured BS 4937 range for thermocouple-extension and compensating-cable enquiries. PVC insulation and sheath are combined with an overall foil screen.

440 Volt · Low Smoke Zero Halogen (LSZH)
Screened cable for equipment-control and signal wiring under the DEF 61-12 reference. Flexible tinned-copper conductors have LSZH insulation and sheath and a tinned-copper braid screen, rated 440 V.

440 volts · Polyvinyl Chloride (PVC)
Small-conductor cable for equipment-control and signal connections. The DEF 61-12 PVC range combines flexible tinned copper and a tinned-copper braid screen at 440 V, in sizes from 0.22…

600/1000 Volts · Polychloroprene (PCP)
Flexible loop-detector cable for traffic-detection wiring, in sizes from 1.5 to 2.5 mm². Tinned copper has EPR insulation and a PCP sheath, with a 600/1000 V rating.

0.63 mm · PVC
Screened, armoured cable for fixed telecommunications and signalling connections. Solid 0.63 mm copper conductors have cellular PE insulation, with an aluminium/Mylar screen, steel-wire armour and a PVC sheath.

Polyethylene
Jelly-filled telecommunications cable with solid copper conductors, cellular PE insulation and a PE sheath. Steel-wire armour surrounds the petroleum-jelly-filled PE bedding for the fixed cable route.

0.64 mm · PVC sheath
Screened ENATS 09-6 cable for utility telecommunications. Tinned-copper pairs of 0.64 mm conductor diameter share a foil screen and a 0.5 mm² drain wire, with steel-wire armour and…

0.50 mm · PVC sheath
ENATS 09-6 telecommunications cable with 0.50 mm solid-copper conductors and PE insulation and bedding. Steel-wire armour and a PVC sheath form the outer construction.

0.50 mm · Polyvinyl Chloride (PVC)
Screened utility telecommunications cable with 0.50 mm copper conductors, PVC insulation and a collective aluminium/Mylar foil screen. A 0.5 mm² drain wire, steel-wire armour and PVC sheath complete…

0.28 mm · PVC sheath
Armoured telecommunications cable for utility circuits using 0.28 mm tinned-copper pairs. PVC insulation and bedding are enclosed by steel-wire armour and a PVC sheath.

0.50 mm · Polyvinyl Chloride (PVC)
ENATS 09-6 cable for fixed utility telecommunications, using 0.50 mm solid-copper conductors. PVC insulation and bedding sit inside steel-wire armour and a PVC outer sheath.

0.64 mm · PVC sheath
Armoured utility telecommunications cable with 0.64 mm tinned-copper pairs. The ENATS 09-6 construction uses PVC insulation and bedding, galvanised steel-wire armour and a PVC sheath.

LSZH
LSZH-sheathed CAT cable range for communication, control and measurement connections under BS EN 50288-7.

LSZH
ICAT communication and control cable range under BS EN 50288-7, with an LSZH outer sheath.

PVC
PVC-sheathed CAT cable range for communication and control connections under BS EN 50288-7.

PVC
PVC-sheathed ICAT cable range for communication and control connections.

LSZH
PROFIBUS cable range for industrial communication links, with an LSZH outer sheath and a BS EN/IEC 61158 reference.

Non-armoured loop feeder for the connection between a traffic-detection loop and its detector equipment. The BS 6346/87 range covers 1.5–2.5 mm².
No products match the current filters.
Cable Range

Prysm Cable supplies screened 11 kV and 33 kV feeders, low-voltage armoured mains and utility control cable for fixed connections around substations…
Application Details ↗
Armoured mains for distribution, LSZH wires for fixed building wiring, and separate fire-alarm and fire-resistant mains ranges for essential circuits. Prysm Cable…
Application Details ↗
Control wiring, instrument loops, fieldbus links and equipment power make different demands on an automation cable. Our range includes YY, SY and…
Application Details ↗
Prysm Cable’s BS6708 range covers Type 20 armoured equipment cable, Type 7 and 7M screened constructions, and Type 307 cable. Separate armoured…
Application Details ↗
From solar array wiring to plant-network feeders, auxiliary power and monitoring, Prysm Cable offers separate cable ranges for each connection. The PV…
Application Details ↗
Armoured telecom pairs, screened instrumentation and PROFIBUS cables serve different signal systems. Prysm Cable’s range separates those connection types so the cable…
Application Details ↗Product Data
Print a product summary or download its listed construction and technical data as CSV.
Cable Range
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read More“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read More