BS5467 Mains Cable - SWA, PVC, 1kV
1kV · Polyvinyl Chloride PVC
BS5467 armoured copper mains cable for fixed power distribution, in the 25–400 mm² range. XLPE insulation, steel-wire armour and a PVC sheath make up this 1 kV mains…
Applications
Prysm Cable supplies armoured power cables, flexible control cables, screened instrumentation cables, marine cables, solar cables and communication cables. Choose your application to see the cable types we offer, the features that matter and the matching products.
Cable Applications
Power, control, instrumentation and communication cable ranges for the projects below.

Prysm Cable supplies screened 11 kV and 33 kV feeders, low-voltage armoured mains and utility control cable for fixed connections around substations…
Application Details ↗
Armoured mains for distribution, LSZH wires for fixed building wiring, and separate fire-alarm and fire-resistant mains ranges for essential circuits. Prysm Cable…
Application Details ↗
Control wiring, instrument loops, fieldbus links and equipment power make different demands on an automation cable. Our range includes YY, SY and…
Application Details ↗
Prysm Cable’s BS6708 range covers Type 20 armoured equipment cable, Type 7 and 7M screened constructions, and Type 307 cable. Separate armoured…
Application Details ↗
Prysm Cable supplies shipboard power and instrument cables, including screened marine pairs and a BFOU mud-resistant range. The cable choice follows the…
Application Details ↗
From solar array wiring to plant-network feeders, auxiliary power and monitoring, Prysm Cable offers separate cable ranges for each connection. The PV…
Application Details ↗
Armoured telecom pairs, screened instrumentation and PROFIBUS cables serve different signal systems. Prysm Cable’s range separates those connection types so the cable…
Application Details ↗
Prysm Cable supplies PAS5308 instrument pairs for field measurements, armoured LSZH instrumentation for protected plant routes, and separate auxiliary mains and temperature-instrument…
Application Details ↗Cable Applications
Browse selected power, control, instrumentation, marine, solar, communications, fire alarm and mining cables.

1kV · Polyvinyl Chloride PVC
BS5467 armoured copper mains cable for fixed power distribution, in the 25–400 mm² range. XLPE insulation, steel-wire armour and a PVC sheath make up this 1 kV mains…

300/500 Volts · PVC
Flexible YY control cable for machine and equipment wiring. Stranded copper conductors have PVC insulation and a PVC sheath, with a 300/500 V rating in the 0.75–50 mm²…

300/500 Volts · LSZH
LSZH-sheathed instrumentation cable with a separate screen around each PE-insulated copper pair. Each pair has a 0.5 mm² drain wire, providing individual screen connections for the 300/500 V…

600/1000 Volts · Halogen free extruded SHF1 compound
Shipboard power cable with tinned copper conductors, XLPE insulation and an SHF1 halogen-free sheath. The IEC 60092-353 range is rated 600/1000 V and covers 1.5–25 mm² circuits.

600V-1000V AC, 1800V DC · Cross-linked halogen-free compound
Solar PV cable for the DC wiring between panels and array equipment. The flexible Class 5 tinned-copper conductor helps route connections at the modules, with cross-linked halogen-free insulation…

LSZH
PROFIBUS cable range for industrial communication links, with an LSZH outer sheath and a BS EN/IEC 61158 reference.

300/500V · Low Smoke Zero Halogen (LSZH)
Enhanced fire-alarm and security cable for 300/500 V system wiring. The construction uses mica-tape or silicone-rubber fire-resistant insulation, an aluminium/polyester screen and an LSZH sheath.

640V to 1100V · Heavy duty chloroprene outer sheath
BS 6708 Type 20 cable for mining and quarry power connections. Flexible Class 5 tinned copper, EPR insulation and a heavy-duty chloroprene sheath are combined with galvanised pliable…

Polyvinyl Chloride (PVC)
Non-armoured BS 4937 range for thermocouple-extension and compensating-cable enquiries. PVC insulation and sheath are combined with an overall foil screen.
Cable Applications
Compare insulation, screening and fire-performance requirements in our technical guides.
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreAn overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreAn emergency circuit may need to keep working during a fire. An LSZH cable addresses smoke and halogen-related characteristics; a flame-retardant cable addresses flame spread. Neither label alone establishes circuit survival. Choosing the cable starts with the required function of the circuit during the fire.