SPWC-CABLE-124
N2XS(F)2Y 22kV Medium Voltage Power Cable - XLPE, PE
N2XS(F)2Y 22kV Medium Voltage Power Cable - XLPE, PE - 35mm to 630mm
N2XS(F)2Y 22 kV power cable with XLPE insulation and a PE sheath, in the 35–630 mm² range.
| Voltage Designation | 22kV |
|---|
Product Details
Cable Construction
01Insulation
XLPE
02Outer Sheath
PE
Product Details
Electrical and Physical Specifications
- Voltage Designation
- 22kV
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
N2XS(F)2Y 22kV Medium Voltage Power Cable - XLPE, PE
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | N2XS(F)2Y 22kV Medium Voltage Power Cable - XLPE, PE | N2XS(F)2Y 11kV Medium Voltage Power Cable - XLPE, PE |
|---|---|---|
| Insulation | XLPE | Cross-Linked Polyethylene (XLPE) |
| Outer Sheath | PE | Polyethylene (PE) |
| Conductor | Not Listed | Stranded Copper Conductor to BS EN 60228 |
| Screen | Not Listed | Copper Wire Screen & Counter Helix Copper Tape |
| Voltage Designation | 22kV | Not Listed |
| Rated Voltage | Not Listed | 6/10 (12)kV |
| Temperature Range | Not Listed | 0°C to +70°C |
| Standard Reference | BS EN / IEC 60332-1-2 · VDE 0276-620 · BS EN 60228 | BS EN / IEC 60332-1-2 · VDE 0276-620 · BS EN 60228 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints