SPWC-CABLE-059
BS6724 3 Core Mains Cable 3.3kV - XLPE, SWA, LSZH
BS6724 3 Core Mains Cable 3.3kV - XLPE, SWA, LSZH - 16mm to 300mm
Three-core 3.3 kV mains cable with XLPE-insulated copper conductors, steel-wire armour and LSZH bedding and sheath. The BS 6724 range covers 16–300 mm² at 1900/3300 V.
| Core Arrangement | 3 Core |
|---|---|
| Rated Voltage | 1900/3300 |
Product Details
Cable Construction
01Conductor
Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360)
02Insulation
Cross-Linked Polyethylene (XLPE)
03Bedding / Inner Sheath
Low Smoke Zero Halogen (LSZH)
04Armour
Steel Wire Armour (SWA)
05Outer Sheath
Low Smoke Zero Halogen (Low Smoke Zero Halogen)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 1900/3300
- Core Arrangement
- 3 Core
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
BS6724 3 Core Mains Cable 3.3kV - XLPE, SWA, LSZH
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS6724 3 Core Mains Cable 3.3kV - XLPE, SWA, LSZH | BS5467 3 Core Mains Cable 3.3kV - XLPE, SWA, PVC |
|---|---|---|
| Conductor | Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360) | Class 2 stranded copper conductor acc BS EN 60228 (previously BS 6360) |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Bedding / Inner Sheath | Low Smoke Zero Halogen (LSZH) | Polyvinyl Chloride (PVC) |
| Armour | Steel Wire Armour (SWA) | Steel Wire Armour (SWA) |
| Outer Sheath | Low Smoke Zero Halogen (Low Smoke Zero Halogen) | Polyvinyl Chloride PVC |
| Rated Voltage | 1900/3300 | 1900/3300 Volts |
| Core Arrangement | 3 Core | 3 Core |
| Temperature Range | Not Listed | Fixed -20°C to +90°C |
| Standard Reference | BS6724 · BS EN 50267 · IEC 60754-1 · BS EN 50268 · IEC 61034 · IEC 60332-1 · IEC 60332-3 · BS EN50265 · BS EN 50266 | BS5467 · BS EN/IEC 60332 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints