PVC Cabinet Wire
Stranded copper H07V-R wire with PVC insulation for fixed wiring and panel connections.
Cable Range
From H07V-R cabinet wire to YY, SY and CY control cable, this range covers building wiring and equipment connections. Compare the voltage, conductor form, metallic layer and rubber, PVC or LSZH coverings for each duty.

Cable Range
Choose PVC YY for the specified control connection, PVC CY where a tinned-copper braid screen is required, or PVC SY where the design calls for steel-wire braid.
Stranded copper H07V-R wire with PVC insulation for fixed wiring and panel connections.
An LSZH flexible single core when the panel or equipment specification calls for halogen-free coverings.
YY multicore control cable for a connection without a specified metallic screen or braid.
SY adds a steel-wire braid for mechanical protection. It is a different choice from a copper braid screen.
CY uses a tinned-copper braid for an electrical screening requirement on the control connection.
H07RN-F flexible mains and control cable with EPR insulation and a PCP sheath.

600/1000 Volts · Polyvinyl Chloride (PVC)
Single-core armoured cable for cathodic-protection system wiring. The 600/1000 V construction has stranded copper, XLPE insulation, steel-wire armour and a PVC sheath, in the 6–185 mm² range.

300/500 Volts · PVC to IEC 60332-1-2
NYMJ cable for fixed domestic and industrial wiring, with PVC insulation and a PVC sheath. The range covers 1.5–16 mm² at 300/500 V.

300/500 Volts · PVC
PVC twin-and-earth cable for fixed building lighting and power wiring. The 300/500 V range combines the circuit conductors and earth connection in one cable, in sizes from 1…

450/750 volts
6491X/H07V-R stranded copper wiring cable for individual circuit conductors in conduit, trunking and equipment enclosures. It has PVC insulation and a 450/750 V rating.

300/500 volts, 120mm2 rated at 600/1000 volts · 1.5–120 mm² · PVC
PVC-insulated and PVC-sheathed cable for surface wiring, covering 1.5–120 mm². Sizes below 120 mm² are rated 300/500 V; the 120 mm² version is rated 600/1000 V.

300/500Volts · Halogen free thermoplastic polymer compound
NHXMH-J cable for fixed domestic and industrial wiring. Copper conductors have XLPE insulation and a halogen-free thermoplastic sheath, with a 300/500 V rating in the 1.5–10 mm² product…

300/500 volts · Low Smoke Zero Halogen (LSZH)
Flexible cord for equipment connections requiring LSZH insulation and sheath. The 318*B/H05ZIZI-F range uses flexible stranded copper and is rated 300/500 V, with a -15°C to +70°C temperature…

300/500 Volts · LSZH
YY cable for flexible equipment-control wiring with LSZH insulation and sheath. Stranded copper conductors form the 300/500 V connection, in sizes from 0.75 to 25 mm².

300/500 Volts · Low Smoke Zero Halogen (LSZH)
CY flexible control cable with copper conductors, LSZH insulation and an LSZH sheath. The 300/500 V range covers 0.75–2.5 mm² equipment-control connections.

300/500 volts · LSZH
SY control cable for equipment wiring requiring steel-wire armour and LSZH materials. It combines stranded copper, LSZH insulation and sheath, and a 300/500 V rating in the 1.5–6…

Flexible single-core copper cable for individual equipment-wiring connections. The 2491B/6701B range has LSZH covering, covers 0.75–240 mm², and has a -15°C to +90°C temperature range.

230-415V · PCP (Polychloroprene) to BS EN 50363
Flexible H07RN-F cable for temporary equipment-power leads. Class 5 copper conductors, EPR insulation and a PCP sheath provide a rubber-cable construction for the stated 230–415 V lead range.

230-415V · Transparent PVC
SY temporary-power cable with stranded copper, PVC insulation and a galvanised steel-wire braid under a transparent PVC sheath. The 2.5–4 mm² lead range is rated 230–415 V.

600/1000 · PVC
Non-armoured 6181X cable for cathodic-protection wiring. A single stranded copper conductor has XLPE insulation and a PVC sheath, with a 600/1000 V rating in the 6–185 mm² range.

600/1000 volts · 6–95 mm² · High-Molecular Weight Polyethylene (HMWPE)
Single-core cathodic-protection cable with PVDF insulation and an HMWPE sheath. The non-armoured copper range covers 6–95 mm² at 600/1000 V, with a -55°C to +105°C temperature range.

300/500 Volts · PVC
Flexible YY control cable for machine and equipment wiring. Stranded copper conductors have PVC insulation and a PVC sheath, with a 300/500 V rating in the 0.75–50 mm²…

300/500 Volts · Transparent PVC
SY flexible control cable with galvanised steel-wire braid beneath a transparent PVC sheath. Stranded copper conductors and PVC insulation form the 300/500 V equipment-control connection.

300/500 Volts · Polyvinyl Chloride (PVC)
Screened CY cable for flexible machine-control connections. A tinned-copper braid surrounds the PVC-insulated copper conductors beneath a PVC sheath, with a 300/500 V rating.

1800/3000V · Polychloroprene (PCP)
Flexible NSGAFÖU cable for equipment-power connections, with tinned copper conductors, EPR insulation and a PCP sheath. The range is rated 1800/3000 V.

450/750 Volts · Thermoplastic Rubber (TPR)
Flat flexible cable for equipment-power and control connections using a flat cable route. Copper conductors have TPR insulation and sheath at 450/750 V, with a -35°C to +65°C…

300/500 volts · Silicone
Silicone-insulated flexible cable for equipment wiring in high-temperature areas. Tinned-copper conductors have silicone insulation and sheath, with a 300/500 V rating and a -60°C to +180°C temperature range.

PVC
Flexible PVC cord for appliance and equipment connections, in the 0.5–2.5 mm² H05V2V2-F range.

CSP
Flexible 318*TQ cable for equipment mains and control connections, with EPR insulation and a CSP sheath. The range covers 0.75–2.5 mm².

Tough-rubber flexible cord for equipment connections in the 0.75–2.5 mm² range, with EPR insulation.

CSP
Flexible 638*TQ mains cable for larger equipment-power connections. The 25–630 mm² range uses EPR insulation and a CSP sheath.

CSP
638*TQ flexible mains cable for equipment connections in the 4–16 mm² range. EPR insulation and a CSP sheath form the specified material construction.

Flexible single-core 6381Y cable for individual equipment and installation connections. The PVC-insulated BS 6004 range covers 6–400 mm².

CSP
Coil-end lead cable connecting winding ends to equipment terminals. The BS 6195/69 Type 4 range uses EPR insulation and a CSP sheath.

PVC-insulated panel and equipment wire in the Tri-Rated cable range, covering 0.5–400 mm² under the BS 6231 reference.

CSP
0361TQ welding cable for the welding-machine output and return connections. EPR insulation and a CSP sheath form the 16–185 mm² lead range.

PCP
Braided tough-rubber flexible cord with a PCP outer sheath, for equipment connections in the 1–16 mm² range.

PCP
H07RN-F flexible mains and control cable with EPR insulation and a PCP sheath, covering 1–630 mm² equipment connections.

1–16 mm² · LSZH
H07ZZ-F/318*ZH flexible mains and control cable with an LSZH sheath, in the 1–16 mm² range.

LSZH
Flexible H07ZZ-F cable for larger mains and control connections, with an LSZH outer sheath in the 25–630 mm² range.

PVC
H07VVH6-F flat cable for equipment power and control connections. PVC insulation and a PVC sheath form the 1.5–95 mm² range.
No products match the current filters.
Cable Range

Armoured mains for distribution, LSZH wires for fixed building wiring, and separate fire-alarm and fire-resistant mains ranges for essential circuits. Prysm Cable…
Application Details ↗
Control wiring, instrument loops, fieldbus links and equipment power make different demands on an automation cable. Our range includes YY, SY and…
Application Details ↗Product Data
Print a product summary or download its listed construction and technical data as CSV.
Cable Range
A cable that can be bent into position is not automatically suitable for repeated machine movement. For a tight route, the useful numbers are the finished cable diameter, the minimum bending radius for that use, and the handling-temperature limit. Conductor class alone cannot answer all three questions.
Read MoreAn overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read More