Airports & Airfields
Terminal distribution supplies switchboards, service areas and baggage equipment. Screened control cables serve building and baggage systems. Runway and taxiway lighting has a separate circuit specification.

Cable Application
Armoured mains for distribution, LSZH wires for fixed building wiring, and separate fire-alarm and fire-resistant mains ranges for essential circuits. Prysm Cable also supplies N2XH Class 5 power cable for fixed equipment connections.
Application Detail
Terminal distribution supplies switchboards, service areas and baggage equipment. Screened control cables serve building and baggage systems. Runway and taxiway lighting has a separate circuit specification.
Building feeders include BS 5467 armoured cables and BS 6724 low-smoke armoured constructions. Lighting and small-power circuits use fixed wiring, while fire alarms and emergency circuits have separate fire performance requirements.
Station feeders, ventilation controls and emergency circuits form separate cable groups in rail and metro buildings. Rolling stock and signalling use their own project specifications.
BS6724 armoured mains and control cable for building-service circuits specifying XLPE insulation with LSZH bedding and sheath, rated 600/1000 V.
6491B / H07Z-R single-core copper wire for LSZH fixed wiring, rated 450/750 V.
Enhanced Fire Alarm & Security Cable - BS5839, BS7629
F2 Fire Resistant Mains Cable 1kV - BS7846, BS6387, MGT, XLPE, SWA, LSZHEnhanced fire-alarm cable for alarm wiring at 300/500 V, and F2 armoured mains for fire-resistant power-cable specifications at 600/1000 V.
N2XH Class 5 power cable combines a flexible copper conductor with XLPE insulation and an LSZH sheath. The stated minimum bending radius is 5D.
Application Detail
An LSZH specification addresses smoke and halogen-related characteristics. An essential circuit may also need a defined fire-resistance test and performance requirement. This is why the ordinary LSZH wiring, alarm cable and fire-resistant mains are separate product choices.
A flexible conductor helps the installer route a fixed connection, but it does not remove the cable’s bending radius. For a specified minimum bending radius of 5D, multiply the selected cable’s overall diameter by five to find the required radius; the gland and approach to the bend also need room.
Application Detail
View specifications or add cables to your enquiry.

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Armoured copper mains cable for fixed 600/1000 V distribution circuits requiring LSZH bedding and sheath. The BS 6724 range combines XLPE insulation and steel-wire armour in sizes from…

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
BS 6724 cable for fixed branch-power and auxiliary-control circuits requiring LSZH materials. Copper conductors, XLPE insulation and steel-wire armour are combined with LSZH bedding and sheath at 600/1000…

450/750 Volts · Low Smoke and Zero Halogen (LSZH)
6491B/H07Z-R wiring cable for individual conductors in protected building and equipment wiring. It combines compacted stranded copper with LSZH material at 450/750 V.

300/500V · Low Smoke Zero Halogen (LSZH)
Enhanced fire-alarm and security cable for 300/500 V system wiring. The construction uses mica-tape or silicone-rubber fire-resistant insulation, an aluminium/polyester screen and an LSZH sheath.

600/1000 volts · LSZH
F2 fire-resistant mains cable for 600/1000 V power circuits, in sizes from 1.5 to 16 mm². Copper conductors and XLPE insulation are combined with steel-wire armour, LSZH bedding…

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Flexible Class 5 copper power cable for equipment connections, with XLPE insulation and an LSZH sheath. This 600/1000 V range has a +90°C temperature rating and a minimum…
Product Data
Print a product summary or download its listed construction and technical data as CSV.
Application Detail
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreAn emergency circuit may need to keep working during a fire. An LSZH cable addresses smoke and halogen-related characteristics; a flame-retardant cable addresses flame spread. Neither label alone establishes circuit survival. Choosing the cable starts with the required function of the circuit during the fire.
Read More