SPWC-CABLE-054
BS5467 Mains Cable - SWA, PVC, 1kV
BS5467 Mains Cable - SWA, PVC, 1kV - 25mm to 400mm1
Copper BS 5467 mains cable for fixed 1 kV power distribution. XLPE insulation, PVC bedding, steel-wire armour and a PVC sheath form the 25–400 mm² range.
| Temperature Range | Fixed -20°C to +90°C |
|---|---|
| Voltage Designation | 1kV |
Product Details
Cable Construction
01Conductor
Class 2 stranded copper conductor acc BS EN 60228 (previously BS 6360)
02Insulation
Cross-Linked Polyethylene (XLPE)
03Bedding / Inner Sheath
Polyvinyl Chloride (PVC)
04Armour
Steel Wire Armour (SWA)
05Outer Sheath
Polyvinyl Chloride PVC
Product Details
Electrical and Physical Specifications
- Temperature Range
- Fixed -20°C to +90°C
- Voltage Designation
- 1kV
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
BS5467 Mains Cable - SWA, PVC, 1kV
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS5467 Mains Cable - SWA, PVC, 1kV | BS5467 Solid Aluminium Core Mains Cable - SWA, PVC, 1kV |
|---|---|---|
| Conductor | Class 2 stranded copper conductor acc BS EN 60228 (previously BS 6360) | Solid Aluminium |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Bedding / Inner Sheath | Polyvinyl Chloride (PVC) | Polyvinyl Chloride (PVC) |
| Armour | Steel Wire Armour (SWA) | Galvanised Steel Wire Armour (SWA) |
| Outer Sheath | Polyvinyl Chloride PVC | Polyvinyl Chloride (PVC) |
| Temperature Range | Fixed -20°C to +90°C | Fixed -20°C to +90°C |
| Voltage Designation | 1kV | 1kV |
| Standard Reference | BS5467 · BS EN 60332-1 | BS5467 · BS EN 60332 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints