SPWC-CABLE-009
6941AX Mains Cable 3.3kV - BS5467, AWA, XLPE
6941AX Mains Cable 3.3kV - BS5467, AWA, XLPE - 120mm to 630mm
Copper 6941AX mains cable for 3.3 kV power connections, in the 120–630 mm² range. XLPE insulation, aluminium-wire armour and a PVC sheath form the 1900/3300 V construction.
| Rated Voltage | 1900/3300 Volts |
|---|---|
| Temperature Range | -15°C to +90°C |
Product Details
Cable Construction
01Conductor
Stranded Plain Annealed Copper Conductor
02Insulation
Cross-Linked Polyethylene (XLPE)
03Bedding / Inner Sheath
PVC
04Armour
Aluminium Wire Armour
05Outer Sheath
PVC
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 1900/3300 Volts
- Temperature Range
- -15°C to +90°C
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
6941AX Mains Cable 3.3kV - BS5467, AWA, XLPE
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | 6941AX Mains Cable 3.3kV - BS5467, AWA, XLPE | 6941AB Mains Cable 3.3kV - BS6724, XLPE, AWA, LSZH |
|---|---|---|
| Conductor | Stranded Plain Annealed Copper Conductor | Class 2 stranded copper conductor according to BS EN 60228 (previously BS 6360) |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Bedding / Inner Sheath | PVC | Low smoke Zero Halogen (LSZH) |
| Armour | Aluminium Wire Armour | Aluminium Wire Armour (AWA) |
| Outer Sheath | PVC | Low smoke Zero Halogen (LSZH) |
| Rated Voltage | 1900/3300 Volts | 1900 to 3300 Volts |
| Temperature Range | -15°C to +90°C | -25°C to +90°C |
| Standard Reference | BS5467 · BS EN 60332-1-2 | BS6724 · BS EN 50267 · IEC 60754-1 · BS EN 50268 · IEC 61034 · IEC 60332-1 · IEC 60332-3 · BS EN 50265 · BS EN 50266 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing