SPWC-CABLE-041
BS6708 Type 21 Mining Cable - EPR, SWA, CP
BS6708 Type 21 Mining Cable - EPR, SWA, CP - 2.5mm to 150mm
BS 6708 Type 21 mining cable with flexible tinned-copper conductors, EPR insulation, pliable steel armour and a heavy-duty chloroprene sheath.
| Rated Voltage | 640V to 1100V |
|---|---|
| Fixed-Service Temperature | −20°C to +85°C |
| Installation Temperature | 5°C to 60°C |
Product Details
Installing in a Cold Working Area
Installation is specified at 5°C to 60°C, while fixed operation extends down to -20°C. A cable that can operate in a cold area may therefore need warmer handling conditions while it is being installed. The two limits answer different questions when planning the work.
Product Details
Cable Construction
01Conductor
Electrolytic, stranded, tinned copper wire IEC 60228 Class 5
02Insulation
Ethylene propylene rubber (EPR)
03Bedding / Inner Sheath
Rubber based bedding compound
04Armour
Galvanized steel pliable armour
05Outer Sheath
Heavy duty chloroprene outer sheath
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 640V to 1100V
- Fixed-Service Temperature
- −20°C to +85°C
- Installation Temperature
- 5°C to 60°C
Product Details
Standards and Technical Topics
XLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreIndividual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreProduct Details
Product Technical Data
BS6708 Type 21 Mining Cable - EPR, SWA, CP
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS6708 Type 21 Mining Cable - EPR, SWA, CP | BS6708 Type 20 Mining Cable - EPR, SWA, CP |
|---|---|---|
| Conductor | Electrolytic, stranded, tinned copper wire IEC 60228 Class 5 | Electrolytic, stranded, tinned copper wire IEC 60228 Class 5 |
| Insulation | Ethylene propylene rubber (EPR) | Ethylene propylene rubber EPR |
| Bedding / Inner Sheath | Rubber based bedding compound | Rubber based bedding compound |
| Armour | Galvanized steel pliable armour | Galvanized steel pliable armour |
| Outer Sheath | Heavy duty chloroprene outer sheath | Heavy duty chloroprene outer sheath |
| Rated Voltage | 640V to 1100V | 640V to 1100V |
| Fixed-Service Temperature | −20°C to +85°C | Not Listed |
| Installation Temperature | 5°C to 60°C | Not Listed |
| Temperature Range | Not Listed | Fixed: -20°C to +85°C |
| Standard Reference | BS6708 | BS6708 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints