SPWC-CABLE-016
BS6346/87 Armoured Loop Feeder Cable
BS6346/87 Armoured Loop Feeder Cable - 1.5mm to 2.5mm
Armoured feeder cable connecting a traffic-detection loop to its detector equipment. Solid copper, PE insulation and bedding, steel-wire armour and a PE sheath form the 1.5–2.5 mm² range.
| Rated Voltage | 600/1000 Volts |
|---|---|
| Temperature Range | -15°C to +70°C |
Product Details
The Feeder Is a Separate Part of the Loop
This is the connection from the detection loop back to the equipment. The wire forming the loop in the road has a separate role and specification. Where the feeder route already has the required mechanical protection, our non-armoured loop-feeder range offers that alternative.
Product Details
Cable Construction
01Conductor
Plain Annealed Solid Copper
02Insulation
Polyethylene (PE)
03Bedding / Inner Sheath
Polyethylene (PE)
04Armour
Galvanised Steel Wire Armour
05Outer Sheath
Polyethylene (PE)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 600/1000 Volts
- Temperature Range
- -15°C to +70°C
Product Details
Standards and Technical Topics
Individual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreCable Size: Cores, Pairs, mm² and Outside Diameter
“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreProduct Details
Product Technical Data
BS6346/87 Armoured Loop Feeder Cable
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS6346/87 Armoured Loop Feeder Cable | BS6346/87 Armoured Traffic Signal Cable |
|---|---|---|
| Conductor | Plain Annealed Solid Copper | Annealed Solid Copper Conductor |
| Insulation | Polyethylene (PE) | Polyvinyl Chloride (PVC) |
| Bedding / Inner Sheath | Polyethylene (PE) | Polyvinyl Chloride (PVC) |
| Armour | Galvanised Steel Wire Armour | Galvanised Steel Wire (SWA) |
| Outer Sheath | Polyethylene (PE) | Polyvinyl Chloride (PVC) |
| Rated Voltage | 600/1000 Volts | 600/1000V |
| Temperature Range | -15°C to +70°C | -15°C to +70°C |
| Standard Reference | BS6346/87 | BS6346/87 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints