SPWC-CABLE-061
6491F BS6387 Fire Resistant Single Core Cable 1kV - LSZH
6491F BS6387 Fire Resistant Single Core Cable 1kV - LSZH - 1.5mm to 16mm
Fire-resistant single-core cable for individual conductors in an emergency-circuit wiring system. The 6491F range combines stranded copper and LSZH covering at 600/1000 V, in sizes from 1.5 to 16 mm².
| Core Arrangement | Single Core |
|---|---|
| Rated Voltage | 600/1000 volts |
| Temperature Range | -10°C to +90°C |
Product Details
The Cable and Its Support System
An emergency circuit also relies on its supports, joints and terminations. Match the cable’s fire-test category to the specified circuit and installation system. A BS 6387 reference identifies the test family; the classification for the supplied cable establishes the relevant performance.
Product Details
Cable Construction
01Conductor
Stranded Plain Annealed Compacted Circular Copper Conductor
02Outer Sheath
Low Smoke and Zero Halogen (LSZH)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 600/1000 volts
- Temperature Range
- -10°C to +90°C
- Core Arrangement
- Single Core
Product Details
Standards and Technical Topics
XLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreLSZH, Flame Retardant or Fire Resistant: Which Cable Does the Circuit Need?
An emergency circuit may need to keep working during a fire. An LSZH cable addresses smoke and halogen-related characteristics; a flame-retardant cable addresses flame spread. Neither label alone establishes circuit survival. Choosing the cable starts with the required function of the circuit during the fire.
Read MoreWill the Cable Fit the Bend and Survive the Movement?
A cable that can be bent into position is not automatically suitable for repeated machine movement. For a tight route, the useful numbers are the finished cable diameter, the minimum bending radius for that use, and the handling-temperature limit. Conductor class alone cannot answer all three questions.
Read MoreProduct Details
Product Technical Data
6491F BS6387 Fire Resistant Single Core Cable 1kV - LSZH
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | 6491F BS6387 Fire Resistant Single Core Cable 1kV - LSZH | F2 Fire Resistant Mains Cable 1kV - BS7846, BS6387, MGT, XLPE, SWA, LSZH |
|---|---|---|
| Conductor | Stranded Plain Annealed Compacted Circular Copper Conductor | Plain Annealed Stranded Copper Conductor |
| Outer Sheath | Low Smoke and Zero Halogen (LSZH) | LSZH |
| Insulation | Not Listed | Cross-Linked Polyethylene (XLPE) |
| Bedding / Inner Sheath | Not Listed | LSZH |
| Armour | Not Listed | Galvanised Steel Wire Armour |
| Rated Voltage | 600/1000 volts | 600/1000 volts |
| Temperature Range | -10°C to +90°C | -10°C to +90°C |
| Core Arrangement | Single Core | Not Listed |
| Standard Reference | BS6387 · IEC 331 · BS EN 50267 · BS EN 50265-2-1 · BS 7211 | BS7846 · BS6387 · BS EN 50267 · IEC 60754 · BS EN 50268 · IEC 61034 · BS EN 50265 · BS EN 50266 · IEC 60332-3 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints