SPWC-CABLE-118
ENATS 09-6 Telecommunications Cable - SCR, SWA
ENATS 09-6 Telecommunications Cable - SCR, SWA - 0.50mm
Screened utility telecommunications cable with 0.50 mm copper conductors, PVC insulation and a collective aluminium/Mylar foil screen. A 0.5 mm² drain wire, steel-wire armour and PVC sheath complete the ENATS 09-6 construction.
| Conductor Diameter | 0.50 mm |
|---|---|
| Temperature Range | -20°C to +70°C |
Product Details
Cable Construction
01Conductor
Solid Plain Annealed Copper Conductors
02Insulation
Polyvinyl Chloride (PVC)
03Screen
Collective Aluminium / Mylar tape screen with 0.5mm2 drain wire
04Bedding / Inner Sheath
Polyvinyl Chloride (PVC)
05Armour
Galvanised Steel Wire Armour
06Outer Sheath
Polyvinyl Chloride (PVC)
Product Details
Electrical and Physical Specifications
- Temperature Range
- -20°C to +70°C
- Conductor Diameter
- 0.50 mm
Product Details
Standards and Technical Topics
Individual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreCable Size: Cores, Pairs, mm² and Outside Diameter
“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreProduct Details
Product Technical Data
ENATS 09-6 Telecommunications Cable - SCR, SWA
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | ENATS 09-6 Telecommunications Cable - SCR, SWA | ENATS 09-6 Telecommunications Cable - SCR, SWA |
|---|---|---|
| Conductor | Solid Plain Annealed Copper Conductors | Solid tinned annealed copper conductors twisted to form pairs |
| Insulation | Polyvinyl Chloride (PVC) | PVC insulated |
| Screen | Collective Aluminium / Mylar tape screen with 0.5mm2 drain wire | Aluminium / mylar foil tape complete with 0.5mm2 drain wire |
| Bedding / Inner Sheath | Polyvinyl Chloride (PVC) | PVC bedding |
| Armour | Galvanised Steel Wire Armour | Galvanised steel wire armour |
| Outer Sheath | Polyvinyl Chloride (PVC) | PVC sheath |
| Temperature Range | -20°C to +70°C | -20°C to +70°C |
| Conductor Diameter | 0.50 mm | 0.64 mm |
| Standard Reference | ENATS 09-6 · BS4066 · IEC 332 | ENATS 09-6 · BS4066 Part 1 · IEC 332 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints