SPWC-CABLE-082
PAS5308 Part2/Type2 Instrumentation Cable, Individually Screened
Individually screened, armoured instrumentation cable under PAS 5308 Part 2 Type 2. Copper pairs have PVC insulation, bedding and sheath, with steel-wire armour and a 300/500 V rating.
| Rated Voltage | 300/500 Volts |
|---|---|
| Temperature Range | -20°C to +65°C |
Product Details
Cable Construction
01Conductor
Plain Annealed Copper Conductors
02Insulation
Polyvinyl Chloride (PVC), laid up to form pairs
03Bedding / Inner Sheath
Polyvinyl Chloride (PVC)
04Armour
Galvanised Steel Wire
05Outer Sheath
Polyvinyl Chloride (PVC)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 300/500 Volts
- Temperature Range
- -20°C to +65°C
Product Details
Standards and Technical Topics
Individual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreCable Size: Cores, Pairs, mm² and Outside Diameter
“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreProduct Details
Product Technical Data
PAS5308 Part2/Type2 Instrumentation Cable, Individually Screened
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | PAS5308 Part2/Type2 Instrumentation Cable, Individually Screened | PAS5308 Part2/Type1 Instrumentation Cable, Individually Screened |
|---|---|---|
| Conductor | Plain Annealed Copper Conductors | Plain Annealed Copper Conductors |
| Insulation | Polyvinyl Chloride (PVC), laid up to form pairs | Polyvinyl Chloride (PVC) |
| Bedding / Inner Sheath | Polyvinyl Chloride (PVC) | Not Listed |
| Armour | Galvanised Steel Wire | Not Listed |
| Outer Sheath | Polyvinyl Chloride (PVC) | Polyvinyl Chloride (PVC) |
| Rated Voltage | 300/500 Volts | 300/500 volts |
| Temperature Range | -20°C to +65°C | -20°C to +65°C |
| Standard Reference | PAS5308 Part2/Type2 · BS EN 50265 · BS EN 50266 · IEC 60332-3-24 · BS4066 | PAS5308 Part2/Type1 · BS EN 50265 · BS EN/IEC 60332-3-24 · BS4066 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints