Automation & Control
Machine connections use YY, CY or SY constructions according to the circuit and screening arrangement. Analogue instruments use screened pairs or triads. Continuous flexing is a distinct duty from fixed equipment wiring.

Cable Application
Control wiring, instrument loops, fieldbus links and equipment power make different demands on an automation cable. Our range includes YY, SY and CY control cable, screened PAS5308 pairs, PROFIBUS cable and N2XH Class 5 power cable.
Application Detail
Machine connections use YY, CY or SY constructions according to the circuit and screening arrangement. Analogue instruments use screened pairs or triads. Continuous flexing is a distinct duty from fixed equipment wiring.
Equipment assemblies combine flexible panel wiring, control cores and separate power leads. The conductor class, screen arrangement and core identification depend on the wiring and termination design.
Switchgear assemblies use flexible single-core conductors for internal power connections, control wiring for coils and auxiliaries, and separate incoming feeders. Panel wire and feeder cables serve different voltage and installation duties.
SY Control Flexible Cable - BS EN 50525-2-11, VDE 0250, PVC
CY Control Flexible Cable - BSEN50525-3-11, VDE 0250, PVCOur 300/500 V SY and CY ranges cover connections between machines and their controls. Both use copper conductors and PVC insulation.
PAS5308 Part1/Type1 Instrumentation Cable, Individually Screened - LSZH
PAS5308 Part1/Type1 Instrumentation Cable, Overall ScreenedPAS5308 pairs for measurement connections between instruments, junction boxes and control panels, with individual or overall screen options.
A dedicated PROFIBUS communication-cable range with an LSZH sheath for the fieldbus connection. The bus-cable variant must match the connected system.
N2XH Class 5 power cable for fixed cabinet and equipment supplies, with XLPE insulation, an LSZH sheath and a stated 5D minimum bending radius.
Application Detail
Mechanical damage and electrical interference are different problems. Where the control design calls for a screen, the CY copper braid is the relevant construction. Selecting SY solely because it also has a metal braid would miss that electrical requirement.
An overall screen surrounds the whole bundle. Individual pair screens also separate neighbouring circuits, which can matter when several low-level analogue loops share one cable. Cable choice and screen terminations need to follow the instrument and grounding design.
Application Detail
View specifications or add cables to your enquiry.

300/500 Volts · Transparent PVC
SY flexible control cable with galvanised steel-wire braid beneath a transparent PVC sheath. Stranded copper conductors and PVC insulation form the 300/500 V equipment-control connection.

300/500 Volts · Polyvinyl Chloride (PVC)
Screened CY cable for flexible machine-control connections. A tinned-copper braid surrounds the PVC-insulated copper conductors beneath a PVC sheath, with a 300/500 V rating.

300/500 Volts · LSZH
LSZH-sheathed instrumentation cable with a separate screen around each PE-insulated copper pair. Each pair has a 0.5 mm² drain wire, providing individual screen connections for the 300/500 V…

300/500 volts · Polyvinyl Chloride (PVC)
Overall-screened PAS 5308 Part 1 Type 1 cable for measurement and control signals. PE-insulated copper conductors share an aluminium/Mylar tape screen with a 0.5 mm² drain wire beneath…

LSZH
PROFIBUS cable range for industrial communication links, with an LSZH outer sheath and a BS EN/IEC 61158 reference.

600/1000 Volts · Low Smoke Zero Halogen (LSZH)
Flexible Class 5 copper power cable for equipment connections, with XLPE insulation and an LSZH sheath. This 600/1000 V range has a +90°C temperature rating and a minimum…
Product Data
Print a product summary or download its listed construction and technical data as CSV.
Application Detail
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreA cable that can be bent into position is not automatically suitable for repeated machine movement. For a tight route, the useful numbers are the finished cable diameter, the minimum bending radius for that use, and the handling-temperature limit. Conductor class alone cannot answer all three questions.
Read More