SPWC-CABLE-036
BS7835 3 Core Armoured Power Cable 22kV - XLPE, PET, SWA, LSZH
BS7835 3 Core Armoured Power Cable 22kV - XLPE, PET, SWA, LSZH - 95mm
Three-core 22 kV power cable for feeders requiring an armoured LSZH construction. Compacted copper conductors, XLPE insulation, semiconductive screens and copper-tape screening sit inside steel-wire armour and LSZH outer materials.
| Core Arrangement | 3 Core |
|---|---|
| Rated Voltage | 22000 Volts |
| Temperature Range | -15°C to +90°C |
Product Details
Cable Construction
01Conductor
Stranded Plain Annealed Circular Compacted Copper Conductors
02Insulation
Cross-Linked Polyethylene (XLPE)
03Screen
Individual or collective overall copper tape screen
04Conductor Screen
Semi-conductive XLPE
05Insulation Screen
Semi-conductive XLPE
06Bedding / Inner Sheath
Low Smoke Zero Halogen (LSZH)
07Armour
SWA (Steel Wire Armoured)
08Outer Sheath
Low Smoke Zero Halogen (LSZH)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 22000 Volts
- Temperature Range
- -15°C to +90°C
- Core Arrangement
- 3 Core
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
BS7835 3 Core Armoured Power Cable 22kV - XLPE, PET, SWA, LSZH
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS7835 3 Core Armoured Power Cable 22kV - XLPE, PET, SWA, LSZH | BS7835 3 CORE ARMOURED POWER CABLE 33kV - XLPE, PET, SWA, LSZH |
|---|---|---|
| Conductor | Stranded Plain Annealed Circular Compacted Copper Conductors | Stranded Plain Annealed Circular Compacted Copper Conductors |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Screen | Individual or collective overall copper tape screen | Individual or collective overall copper tape screen |
| Conductor Screen | Semi-conductive XLPE | Semi-conductive XLPE |
| Insulation Screen | Semi-conductive XLPE | Semi-conductive XLPE |
| Bedding / Inner Sheath | Low Smoke Zero Halogen (LSZH) | Low Smoke Zero Halogen (LSZH) |
| Armour | SWA (Steel Wire Armoured) | SWA (Steel Wire Armoured) |
| Outer Sheath | Low Smoke Zero Halogen (LSZH) | Low Smoke Zero Halogen (LSZH) |
| Rated Voltage | 22000 Volts | 33000 Volts |
| Temperature Range | -15°C to +90°C | -15°C to +90°C |
| Core Arrangement | 3 Core | 3 CORE |
| Standard Reference | BS7835 · BS EN/IEC 60754-1 · BS EN/IEC 60228 · BS EN/IEC 60332-1-2 | BS7835 · BS EN/IEC 60754-1 · BS EN/IEC 60228 · BS EN/IEC 60332-1-2 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints