SPWC-CABLE-094
NEK606 BFOU Power & Instrumentation Cable - Mud Resistant
NEK606 BFOU Power & Instrumentation Cable - Mud Resistant - 0.75mm to 35mm
BFOU cable range for offshore power and instrumentation connections. Copper conductors and EPR insulation are enclosed by tinned-copper wire braid, halogen-free mud-resistant bedding and a mud-resistant sheath.
| Rated Voltage | 600/1000 volts; instrumentation circuits: 150-250 Volts |
|---|---|
| Temperature Range | -40°C (fixed installation) to +90°C |
Product Details
Cable Construction
01Conductor
Copper Conductor
02Insulation
Ethylene Propylene (EPR)
03Bedding / Inner Sheath
Halogen Free Mud Resistant Bedding
04Armour
Tinned copper wire braid
05Outer Sheath
Mud resistant sheath
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 600/1000 volts; instrumentation circuits: 150-250 Volts
- Temperature Range
- -40°C (fixed installation) to +90°C
Product Details
Standards and Technical Topics
XLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreIndividual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreProduct Details
Product Technical Data
NEK606 BFOU Power & Instrumentation Cable - Mud Resistant
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | NEK606 BFOU Power & Instrumentation Cable - Mud Resistant | NEK606 RFOU Power & Instrumentation Cable - Mud Resistant |
|---|---|---|
| Conductor | Copper Conductor | Copper Conductor |
| Insulation | Ethylene Propylene (EPR) | EPR |
| Bedding / Inner Sheath | Halogen Free Mud Resistant Bedding | Halogen Free Mud Resistant Bedding |
| Armour | Tinned copper wire braid | Tinned copper wire braid |
| Outer Sheath | Mud resistant sheath | Mud resistant sheath |
| Rated Voltage | 600/1000 volts; instrumentation circuits: 150-250 Volts | Power Cable 600/1000 Volts; instrumentation circuits: 150-250 Volts |
| Temperature Range | -40°C (fixed installation) to +90°C | -40°C (fixed installation) to +90°C |
| Standard Reference | NEK606 · IEC 60228 · IEC 60092-353 · IEC60754-1 · IEC60332-3 · IEC61034-1,2 | NEK606 · IEC 60228 · IEC 60092-353 · IEC60754-1 · IEC60332-3 · IEC61034-1 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints