SPWC-CABLE-051
N2XH Mains Cable - Non-Armoured, LSZH
N2XH Mains Cable - Non-Armoured, LSZH - 1.5mm to 400mm
Non-armoured N2XH cable for fixed 600/1000 V power distribution. Copper conductors have XLPE insulation and an LSZH sheath, in the 1.5–400 mm² range.
| Rated Voltage | 600/1000 Volts |
|---|---|
| Temperature Range | +90°C |
Product Details
Where the Route Supplies the Protection
This N2XH range suits a power-cable schedule calling for a non-armoured LSZH cable. Where the route requires steel-wire armour within the cable, compare the BS 6724 mains range. The two choices address different mechanical-protection arrangements.
Product Details
Cable Construction
01Conductor
Conductor Up to 6mm2: Class 1 solid copper conductor | Above 10mm2 : Class 2 stranded copper conductor
02Insulation
Cross-Linked Polyethylene (XLPE) Type 2XI1
03Outer Sheath
LSZH (Low Smoke Zero Halogen) Type HM4
04Armour
Non-armoured
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 600/1000 Volts
- Temperature Range
- +90°C
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
N2XH Mains Cable - Non-Armoured, LSZH
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | N2XH Mains Cable - Non-Armoured, LSZH | NYYJ Mains & Control Cable - Non-Armoured, PVC |
|---|---|---|
| Conductor | Conductor Up to 6mm2: Class 1 solid copper conductor | Above 10mm2 : Class 2 stranded copper conductor | Not Listed |
| Insulation | Cross-Linked Polyethylene (XLPE) Type 2XI1 | PVC (Poly Vinyl Chloride) |
| Outer Sheath | LSZH (Low Smoke Zero Halogen) Type HM4 | PVC (Poly Vinyl Chloride) |
| Armour | Non-armoured | Non-armoured |
| Rated Voltage | 600/1000 Volts | 600/1000 Volts |
| Temperature Range | +90°C | -30°C to +70°C |
| Conductor Cross-Section | Not Listed | 1.5–16 mm² |
| Standard Reference | VDE 0276 | IEC 60502-1 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints