SPWC-CABLE-088
Marine & Offshore Fire-Resistant EPR Instrumentation Cable - BS7917/6883, UKOOA
Marine & Offshore Cable - Fire Resistant, EPR Individually Screened - BS7917/6883, UKOOA
Fire-resistant marine instrumentation cable with individually screened circuit groups. Tinned-copper pairs, triples or quads use mica-glass tape and EPR GP4 insulation beneath steel-wire braid and an LSZH SW4 sheath, rated 150/250 V.
| Rated Voltage | 150/250 Volts |
|---|---|
| Temperature Range | -40°C (fixed installation) to +90°C |
Product Details
Cable Construction
01Conductor
Tinned stranded circular copper conductor
02Insulation
MICA Glass Tape (MGT) with EPR GP4 insulation laid in pairs, triples or quads. Wrapped in polyester tape
03Screen
Aluminium-backed polyester foil screen
04Bedding / Inner Sheath
LSF Flame retardant halogen free bedding
05Armour
Galvanised steel wire armour braid with PET tape over armour
06Outer Sheath
Low Smoke Zero Halogen (LSZH) SW4
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 150/250 Volts
- Temperature Range
- -40°C (fixed installation) to +90°C
Product Details
Standards and Technical Topics
XLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreIndividual or Overall Screens for Instrument Cables?
An overall screen surrounds the complete group of pairs. Individual screens surround each pair, helping reduce coupling between circuits inside the cable. For several low-level analogue loops sharing one cable, the pair-by-pair separation can be the important difference. A screen around the outside cannot provide the same internal boundaries.
Read MoreProduct Details
Product Technical Data
Marine & Offshore Fire-Resistant EPR Instrumentation Cable - BS7917/6883, UKOOA
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | Marine & Offshore Fire-Resistant EPR Instrumentation Cable - BS7917/6883, UKOOA | Marine & Offshore Cable - Fire Resistant, EPR Overall Screened - BS7917/6883, UKOOA |
|---|---|---|
| Conductor | Tinned stranded circular copper conductor | Tinned stranded circular copper conductor |
| Insulation | MICA Glass Tape (MGT) with EPR GP4 insulation laid in pairs, triples or quads. Wrapped in polyester tape | MICA Glass Tape (MGT) with EPR GP4 insulation laid in pairs, triples or quads. Wrapped in polyester tape |
| Screen | Aluminium-backed polyester foil screen | Overall screened with aluminium backed polyester tape |
| Bedding / Inner Sheath | LSF Flame retardant halogen free bedding | LSF Flame retardant halogen free bedding |
| Armour | Galvanised steel wire armour braid with PET tape over armour | Galvanised steel wire armour braid with PET tape over armour |
| Outer Sheath | Low Smoke Zero Halogen (LSZH) SW4 | Low Smoke Zero Halogen (LSZH) SW4 |
| Rated Voltage | 150/250 Volts | 150/250 volts |
| Temperature Range | -40°C (fixed installation) to +90°C | -40°C to +90°C |
| Standard Reference | BS7917/6883 · BS7917 · BS6883 · IEC60332-1 · IEC60332-3-22 · IEC60754-1,2 · IEC61034-1,2 · IEC60331-21 | BS7917/6883 · BS7917 · BS6883 · IEC60332-1 · IEC60332-3-22 · IEC60754-1,2 · IEC61034-1,2 · IEC60331-21 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints