SPWC-CABLE-005
BS5467 Solid Aluminium Core Mains Cable - SWA, PVC, 1kV
BS5467 Solid Aluminium Core Mains Cable - SWA, PVC, 1kV - 25mm to 300mm
Solid-aluminium BS 5467 cable for fixed 1 kV mains and distribution circuits. The 25–300 mm² range has XLPE insulation, PVC bedding and sheath, and galvanised steel-wire armour.
| Temperature Range | Fixed -20°C to +90°C |
|---|---|
| Voltage Designation | 1kV |
Product Details
Comparing an Aluminium Feeder with Copper
Aluminium can reduce conductor weight, but the electrical design may require a larger cross-section than copper. The comparison also needs aluminium-compatible terminals. Our copper BS 5467 mains range offers the same broad XLPE/SWA/PVC material arrangement with stranded copper, so compare the selected sizes and complete connections rather than equal-mm² prices.
Product Details
Cable Construction
01Conductor
Solid Aluminium
02Insulation
Cross-Linked Polyethylene (XLPE)
03Bedding / Inner Sheath
Polyvinyl Chloride (PVC)
04Armour
Galvanised Steel Wire Armour (SWA)
05Outer Sheath
Polyvinyl Chloride (PVC)
Product Details
Electrical and Physical Specifications
- Temperature Range
- Fixed -20°C to +90°C
- Voltage Designation
- 1kV
Product Details
Standards and Technical Topics
Copper or Aluminium Cable? Cost, Space and Installation
Copper is often the practical choice when cable space and equipment connections are tight. Aluminium is worth considering for larger fixed feeders when conductor cost and weight matter. A useful price comparison starts with cables sized for the same electrical duty, including the connections needed at each end.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreWhy Single-Core AC Cables Use Aluminium Wire Armour
For an individual AC phase, aluminium wire armour avoids the magnetic losses associated with steel armour around a single core. That is why our single-core 11 kV cable uses AWA, while the three-core 11 kV range uses SWA. The aluminium is in the armour; both of these ranges have copper power conductors.
Read MoreProduct Details
Product Technical Data
BS5467 Solid Aluminium Core Mains Cable - SWA, PVC, 1kV
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | BS5467 Solid Aluminium Core Mains Cable - SWA, PVC, 1kV | BS5467 Mains Cable - SWA, PVC, 1kV |
|---|---|---|
| Conductor | Solid Aluminium | Class 2 stranded copper conductor acc BS EN 60228 (previously BS 6360) |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Bedding / Inner Sheath | Polyvinyl Chloride (PVC) | Polyvinyl Chloride (PVC) |
| Armour | Galvanised Steel Wire Armour (SWA) | Steel Wire Armour (SWA) |
| Outer Sheath | Polyvinyl Chloride (PVC) | Polyvinyl Chloride PVC |
| Temperature Range | Fixed -20°C to +90°C | Fixed -20°C to +90°C |
| Voltage Designation | 1kV | 1kV |
| Standard Reference | BS5467 · BS EN 60332 | BS5467 · BS EN 60332-1 |
Product Details
Cable Manufacturing and Packing
Cable Manufacturing


Reel Packing and Restraints