SPWC-CABLE-096
N2XH Class 5 Flexible LSZH LV Power Cable
Flexible Class 5 copper power cable for equipment connections, with XLPE insulation and an LSZH sheath. This 600/1000 V range has a +90°C temperature rating and a minimum bending radius of five overall cable diameters.
| Rated Voltage | 600/1000 Volts |
|---|---|
| Temperature Rating | +90°C |
| Minimum Bending Radius | 5 x overall diameter |
Product Details
Allow Space for the Bend
A 5D limit means that a cable with a 20 mm overall diameter would need a 100 mm bend radius. Use the finished diameter of the ordered cable size for that calculation. Conductor cross-section alone does not tell you how much space the bend needs.
Product Details
Cable Construction
01Conductor
Flexible class 5 stranded copper
02Insulation
Cross-Linked Polyethylene (XLPE)
03Outer Sheath
Low Smoke Zero Halogen (LSZH)
Product Details
Electrical and Physical Specifications
- Rated Voltage
- 600/1000 Volts
- Temperature Rating
- +90°C
- Minimum Bending Radius
- 5 x overall diameter
Product Details
Standards and Technical Topics
Will the Cable Fit the Bend and Survive the Movement?
A cable that can be bent into position is not automatically suitable for repeated machine movement. For a tight route, the useful numbers are the finished cable diameter, the minimum bending radius for that use, and the handling-temperature limit. Conductor class alone cannot answer all three questions.
Read MoreXLPE or LSZH? You May Need Both
A building specification can require XLPE insulation and LSZH bedding and sheath in the same cable. XLPE describes the insulation around the conductor; LSZH describes smoke and halogen-related characteristics. An XLPE/PVC cable therefore meets a different material requirement from an XLPE/LSZH cable.
Read MoreCable Size: Cores, Pairs, mm² and Outside Diameter
“4 × 25 mm²” describes four conductors, each with a nominal area of 25 mm². It does not describe the cable’s outside diameter. Pair counts, conductor area and finished diameter each answer a different ordering question; mixing them up can produce the wrong cable or the wrong gland.
Read MoreProduct Details
Product Technical Data
N2XH Class 5 Flexible LSZH LV Power Cable
Compare with Another Cable
Product Comparison
Cable Constructions Side by Side
Choose two cable products to compare their construction, ratings and stated service conditions.
| Construction Field | N2XH Class 5 Flexible LSZH LV Power Cable | BS 5467 Armoured Power & Control Cable, 1.5–16 mm² |
|---|---|---|
| Conductor | Flexible class 5 stranded copper | Class 2 stranded copper conductor acc BS EN 60228 (previously BS 6360) |
| Insulation | Cross-Linked Polyethylene (XLPE) | Cross-Linked Polyethylene (XLPE) |
| Outer Sheath | Low Smoke Zero Halogen (LSZH) | PVC (Polyvinyl Chloride) |
| Bedding / Inner Sheath | Not Listed | PVC (Polyvinyl Chloride) |
| Armour | Not Listed | SWA (Steel Wire Armour) |
| Rated Voltage | 600/1000 Volts | Not Listed |
| Temperature Rating | +90°C | Not Listed |
| Minimum Bending Radius | 5 x overall diameter | Not Listed |
| Temperature Range | Not Listed | Fixed -20°C to +90°C |
| Conductor Cross-Section | Not Listed | 1.5–16 mm² |
| Standard Reference | IEC 60502-1 · IEC 60288 · IEC 60332-3-24 · IEC60754-1 · IEC 61034-2 · IEC 60332-1 | BS 5467 · BS EN/IEC 60332-1-2 |